A P P E N D I X
AC Power Requirements
In the United States, the EVOi.324 is supplied with an Edison type plug. For other countries, the correct plug must be used in accordance with the local requirements. For Europe and the rest of the world the correct AC supply lead will be supplied.
Voltage Requirements
EVOi.324 will operate continuously provided the AC Voltage falls within the following ranges:
Standard AC Voltage | Voltage Range | Frequency |
120v | +/- 10% | 50/60Hz |
230v | +/- 10% | 50/60Hz |
Brown-out Conditions
If the voltage falls below this range, the EVOi.324 will
To avoid
Current Requirements
EVOi.324 will not draw a continuous current. Acting as a dynamic load on the AC supply, the current drawn will vary dependant on the operating level, e.g. quiet levels and loud levels in the program.
Understanding the amount of current drawn is essential when using EVOi.324.
The EVOi.324 is capable of drawing peak currents of up to 18 Amps. Any cabling used should be of a suitable gauge to reflect this. Inadequate cabling can cause large voltage drops over distance and potentially cause
ALWAYS CONSULT A QUALIFIED ELECTRICIAN
EVOi.324 Sensitivity Chart
| Electrical Input | Acoustic Output | |
|
|
| Measured SPL |
dBu |
| Volts (AC RMS) | (dB re: 20uPa) |
| 0.04 | 91 | |
| 0.08 | 96 | |
| 0.14 | 101 | |
| 0.25 | 106 | |
| 0.44 | 110 | |
0 |
| 0.78 | 116 |
5 |
| 1.38 | 118 |
8 |
| 1.95 | 120 |
10 |
| 2.45 | 122 |
101 dB = Equivalent 1w/1m Specification
21
EVOi.324