Heat Controller HMC30AS-1, HMC30BS-1, HMH30AS-1 Remove the front right side panel by the arrow

Page 7

BRemove the front right side panel by the arrow.

The connector can be disconnected by pulling it while pressing the connector's hook.

Remove the 1 screw for fixing low panel.

Main PCB

Low panel

CRemove the lower panel by the arrow.

Take care not to scratch the wall and mat to drop.

Lower panel

CAUTION

When install, make sure that the remaining parts must be removed clearly so as not to damage the piping and drain hose, especially power cord and connecting cable.

For left rear piping

ARoute the indoor tubing and the drain hose in the direction of rear left.

BInsert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

CTape the tubing, drain hose and the connecting cable. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit.

Loop

 

Connecting

Gas side

piping

cable

 

Drain hose

Liquid side

piping

NOTE: If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recommended.

DIndoor unit installation

Hook the indoor unit onto the upper portion of the installation plate.(Engage the three hooks of the rear top and rear lower of the indoor unit with the upper edge and lower edge of the installation plate.) Ensure that the hooks are properly seated on the installation plate by moving it left and right.

Installation plate

Setting line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain hose

7

Indoor unit

Three upper hooks

Installation plate

Three lower hooks

Image 7
Contents HMC30AS-1/HMH30AS-1, HMC30BS-1/HMH30BS-1Single-Zone Two type B screws Installation OverviewRefer to For right rear pipingDo not install it yourself customer Following should be Always Observed for SafetyPiping length and elevation Installation of INDOOR, Outdoor UnitRooftop Installations Select the best locationIndoor How to mount installation plateInstallation Plate Type a screw Drill a hole in the wallFlaring work Flaring Work and Connection of PipingConnection of piping -Indoor Remove the front right side panel by the arrow Indoor unit installationRemove the lower panel by the arrow Wrap the insulation material around the connecting portion Tighten the flare nut with a wrench Connecting cableSuction Evaporator 84.2kg.mSection Reinstall the parts to the original positionFor left piping. Follow the instruction below Installation Information For left piping Good caseBad case 30k Connection of the drain hoseConnection of piping -Outdoor Follows the arrow on the wrenchConnect the cable to the Indoor unit Wiring must be as following diagramAWG #20 Outdoor Unit Connect the cable to the outdoor unitDrain piping Checking the drainageRemove the right side panel Remove the lower panel by the arrow To check the drainageSeal small openings around pipings with a gum type sealer Form the pipingPreparation AIR PurgingAir purging Air purging with vacuum pumpEvacuation Soap water methodFinishing the job Charging Settlement of outdoor unit Prepare remote controlPump Down Procedure Test RunningMemo Memo No A20001V

HMC30AS-1, HMH30BS-1SINGLE-ZONE, HMH30AS-1, HMC30BS-1 specifications

The Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 are cutting-edge HVAC systems designed to provide optimal comfort and efficiency in both residential and commercial settings. These models embody the latest advancements in heating and cooling technology, making them ideal choices for anyone looking to enhance their indoor environment.

One of the standout features of these heat controllers is their energy efficiency. With advanced inverter technology, these products adjust compressor speed based on the heating or cooling demand, significantly reducing energy consumption compared to traditional systems. This not only lowers utility bills but also reduces environmental impact, making them a sustainable choice for eco-conscious consumers.

The HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 also come with programmable thermostats, allowing users to set specific temperature schedules according to their daily routines. This convenience ensures that spaces are always at the desired temperature when occupied, providing a perfect balance between comfort and energy conservation.

Another impressive characteristic is their quiet operation. These systems are engineered with sound-dampening technology, minimizing noise levels and ensuring a peaceful indoor atmosphere. This is especially beneficial for bedrooms, offices, or any spaces where tranquility is essential.

Durability and reliability are also hallmarks of these models. Built with high-quality materials and robust components, they are designed to withstand varying environmental conditions while providing consistent performance. The heat controllers also come with comprehensive warranties, giving users added peace of mind regarding their investment.

In addition to their efficiency and durability, these systems offer versatile installation options. Whether it's a compact single-zone setup or a larger installation, the HMC30 series is adaptable, making it suitable for various building layouts.

With their modern design and user-friendly interfaces, these heat controllers blend seamlessly into contemporary spaces. Smart technology options enable integration with mobile apps and smart home systems, allowing for remote monitoring and adjustment.

From energy-saving features to quiet operation, the Heat Controller HMC30AS-1, HMH30AS-1, HMH30BS-1 SINGLE-ZONE, and HMC30BS-1 represent the pinnacle of heating and cooling solutions, meeting the diverse needs of today's consumers.