Heat Controller 7602-443 user manual Menu Navigation Shortcuts, Operating Mode Selection

Page 3

Heat Controller, Inc.

7602-443 COMMUNICATING, PROGRAMMABLE THERMOSTAT

User Manual

 

 

 

The 7602-443 Communicating, Programmable Thermostat is the perfect compliment to your geothermal heat pump system and represents a significant advancement in thermostat communicating technology. For homeowners, the 7602-443 provides highly customizable climate control features designed to maximize comfort and reduce the amount of energy consumed by your geothermal heat pump system. Please read the following instructions carefully to maximize the comfort and cost-saving potential of your geothermal heat pump system.

Menu Navigation Shortcuts

1.From any other screen than the home screen, hold down the left arrow button ( ) to return to the home screen.

2.From the home screen, hold the left arrow button ( ) to go to the System Status screen.

1.0 Operating Mode Selection

To set the Operating Mode of your thermostat, navigate to the MODE user option on the Home Screen using the left/right arrow buttons and press the center button. The Operating Mode Menu shows the possible Operating Modes with the currently active Operating Mode highlighted. Use the up/ down arrow buttons to select the desired Mode for use and press the center button to save your selection. The following Modes are available:

Off (default): No equipment operation

Auto: Thermostat automatically controls the equipment to run either heating or cooling depending on the setpoints.

Cool: Thermostat controls cooling equipment depending on Cooling setpoint

Heat: Thermostat controls heating equipment depending on Heating setpoint

Emergency Heat: Thermostat controls auxiliary heat. No compressor operation.

SYSTEM STATUS

LT1 TEMP

 

38.1

LT2 TEMP

 

79.9

COMP DISCHARGE

157.7

HOT WATER EWT

121.5

LEAVING AIR

 

75.1

LEAVING WATER

73.3

ENTERING WATER

78.5

ECM BLOWER RPM

550

ECM TARGET CFM

800

ECM BLWR STATIC

0.5

PUMP WATTS

 

140

FLOW RATE GPM

7.4

PUMP SPEED

 

60%

PREVIOUS

 

 

10/13/11

8:27 AM

 

FAN AUTO

RH 41%

HUMID ON

69°

AUTO

 

SETPOINT

 

HEAT 62

 

COOL 82

RH TEMP MODE FAN MENU OPERATING MODE MENU

OFF

AUTO

COOL

HEAT

EMERGENCY HEAT

CHANGE MODE

PREVIOUS SAVE

3

Image 3
Contents Communicating, Programmable Thermostat Table of Contents Menu Navigation Shortcuts Operating Mode SelectionTemperature Adjustment Fan Mode SelectionChange SET Temp Previous Save Setpoint Heat Cool RH Temp Mode FAN Menu Humidity Control Humidity Level AdjustmentMain Menu Options Overview SettingsHold Menu RH Temp Mode FAN Menu Main MenuMain Menu Main Menu SET Date and TimePermanent Hold this Temperature Until 500 PMLeave Auto Program Menu CopyHeat Cool FAN AutoOffsets Other Settings Screen SettingsProgram Settings Smart RecoveryProgrammed Demand Reduction FAN Operation Programmed Demand Reduction ModeDemand Reduction Option for Program Operation Programmed Demand Reduction Operation For ClimadryTUE Fault Staus Active FaultFault Code E2 High Refrig Pressure Programmed Demand Reduction Schedule Start END Time MONTemperature Status Main Menu SET Date and Time Hold Program FAN Mode Settings Security LockoutTotal Keypad Lockout Select Option Previous Save Night Setback FAN Operation Service NeededRevision History