4.0 Humidity Level Adjustment
NOTE 1: The thermostat must be configured by installer for humidity control to access the humidity setpoint(s).
To adjust the Relative Humidity level on your thermostat, use the left/right arrow buttons to select the RH user option on the Home Screen and then press the center button. The Humidity Control screen shows either one (with Humidification or Dehumidification enabled alone) or both (with BOTH enabled) humidity setpoints. Adjust the setpoints using the up/down arrow buttons. Press the center button to save changes.
•Humidification Setpoint (default 40%): options: 10% to 45% (in 5% increments)
NOTE: Humidifier must be installed to set humidification setpoint.
•Dehumidification Setpoint (default 60%): options: 45% to 80% (in 5% increments)
NOTE 2: The thermostat forces a 10%
the Humidification setpoint may be automatically reduced to enforce a 10%
NOTE 3: If an outdoor sensor is present, the Humidification setpoint will be calculated automatically for optimal comfort.
10/12/11 | 5:22 PM |
| FAN AUTO |
RH 38% | HUMID ON |
70° | AUTO |
SETPOINT
HEAT 70
COOL 78
RH TEMP MODE FAN MENU
HUMIDITY CONTROL
42%
HUMIDITY
HUMIDITY SETTING 40%
DEHUMID SETTING | 60% |