Heat Controller R-410A installation instructions VI. Standard Unit Features 61⁄2 and 71⁄2

Page 6

VI. STANDARD UNIT FEATURES — 612 AND 712

CABINET — Galvanized steel with a durable powder coat paint finish. The cabinet front and sides are formed into a one piece unitized design with stamped louvers to provide protection for the condenser coils.

SERVICE ACCESS — Control box with separation between line and control voltages, as well as compressor and other refrigerant controls are accessible through removable top and side panels (without affecting normal operation of unit).

Condenser fan motors are mounted on removable top panels which bring the motors out to you and expose entire condenser coil for cleaning.

COMPRESSOR — Hermetically sealed with internal high temperature protection and durable insulation on motor windings. The compressor is mounted on rubber grommets to reduce vibration and noise.

CONDENSER COILS — Constructed with copper tubes and aluminum fins mechanical- ly bonded to tubes for maximum heat transfer capabilities. All coil assemblies are leak tested.

REFRIGERANT CONNECTIONS — All field sweat joints are made external of the unit and are located close to the ground for a neat looking installation.

LOW AMBIENT CONTROL — A pressure sensitive fan cycling control allows operation of units down to to 0°F.

HIGH PRESSURE CONTROL — Manual reset control deactivates system if abnormally high pressure occurs.

LOW PRESSURE CONTROL — Automatic reset control deactivates system if abnor- mally low pressure or refrigerant loss occurs.

SERVICE VALVES — Standard on liquid line and suction line. Allows outdoor section to be isolated from indoor coil.

FILTER DRIER — Standard, field installed. Helps maintain system cleanliness.

CONDENSER FAN MOTORS — Direct-drive, PSC single-phase motors.

TRANSFORMER — Step down type, from Line to 24 volts. (Refer to Figure 2.)

CONTACTOR — (Refer to Figure 2.) The contactor is an electrical switch which oper- ates the compressor and condenser fans. Its 24 volt coil is activated through the High Pressure Control and Low Pressure Control on a call for cooling.

CAPACITORS — Help provide starting torque necessary to boost the condenser fan motors to operating speed by directing their stored energy to the starter winding in step with the running winding.

EQUIPMENT GROUND — Lug for field connection of ground wire.

TESTING — All units are run tested at the factory prior to shipment.

FIGURE 2

CAPACITOR

LOW AMBIENT

612 & 712 TON FEATURES

CONTROL

CONTROL

BOX

LOW VOLTAGE

CONNECTION

 

 

 

 

 

 

HIGH VOLTAGE

 

 

 

 

 

 

ENTRY

 

 

COMPRESSOR CONTACTOR

CRANKCASE

SUCTION

LIQUID

LOW VOLTAGE

 

 

 

 

 

HEATER

VALVE

VALVE

ENTRY

CONTROL TRANSFORMER

SCROLL

LOW

HIGH PRESSURE

 

PRESSURE

 

 

 

 

 

 

 

COMPRESSOR

SWITCH

SWITCH

 

6

Image 6
Contents Heatcontroller Table of Contents Safety Information II. Introduction III. Checking Product ReceivedIV. Equipment Protection from the Environment WHY USE AN AIR Cooled Split SYSTEM? VI. Standard Unit Features 61⁄2 and 71⁄2 VII. Installation Important Message to OwnerInspection and Handling Slab Installation Installation GeneralRooftop Installation Refer to Figure Order PartsVIII. Refrigerant Piping Data Installation of Piping Typical Piping Recommendations Refrigerant Piping Feet XII. Wire Routing VIX. Wiring Electrical PowerXI. Power Wiring XV. Leak TestingSpecification of R-410A XVI. R-410A RefrigerantQuick Reference Guide for R-410A Replacement Units XVII. Evacuation and ChargingEvaporator Coil Charging Hints XIX. Accessories ANTI-SHORT Cycle TimerXVIII. Sequence of Operation 61⁄2 and 71⁄2 TON Sight Glass / Moisture Indicator Liquid Pressure ControlLiquid Line Solenoid Valve Charge Charts XX. Miscellaneous61⁄2 TON Condenser 155 160 165 71⁄2 TON Condenser with 10 TON EvaporatorLOW Pressure Switch LPC Maintenance and OperationHigh Pressure Switch HPC ContactorTroubleshooting Filter
Related manuals
Manual 16 pages 37.95 Kb

R-410A specifications

The Heat Controller R-410A is an advanced refrigerant used in various heating and cooling applications, particularly in residential and commercial air conditioning systems. Recognized for its efficiency and eco-friendliness, R-410A has become a popular choice among HVAC manufacturers and professionals.

One of the main features of R-410A is its high efficiency. It operates at a higher pressure than traditional refrigerants, which allows it to transfer heat more effectively. This results in improved energy efficiency ratings (SEER and EER) for systems utilizing R-410A, leading to lower energy bills and reduced environmental impact.

R-410A is also known for its environmental sustainability. Unlike its predecessor, R-22, R-410A has zero ozone depletion potential (ODP) due to its composition of hydrofluorocarbons (HFCs). Although it does have a global warming potential (GWP), the advancements in technology have made R-410A a more environmentally friendly option compared to many older refrigerants.

Developed through innovative technological advancements, R-410A systems often incorporate variable speed compressors and efficient heat exchangers. These technologies allow for better modulation of cooling and heating outputs, ensuring that the indoor environment remains comfortable while using the least amount of energy possible.

Another significant characteristic of R-410A is its compatibility with a wide range of HVAC equipment. Many new air conditioning systems are designed specifically to use R-410A, which has led to the creation of a robust market for these units. Additionally, R-410A systems tend to require less maintenance and have longer lifespans compared to those using older refrigerants.

Safety is another consideration for R-410A users. While R-410A is non-toxic and non-flammable, technicians who work with this refrigerant need to be trained and certified due to its high-pressure properties. Proper handling and installation are crucial to ensure system efficiency and reliability.

In summary, the Heat Controller R-410A stands out in the HVAC industry for its efficiency, environmental benefits, advanced technologies, and compatibility with modern systems. As the industry continues to evolve, R-410A remains a key player, paving the way towards more sustainable and efficient heating and cooling solutions.