VIII. REFRIGERANT PIPING DATA

CONDENSING UNITS ARE SHIPPED WITH A NITROGEN HOLDING CHARGE.

EVACUATE CONDENSING UNIT BEFORE CHARGING WITH REFRIGERANT.

TABLE 3

REFRIGERANT PIPING DATA

Equivalent Length (ft.) [m] of straight type “L” tubing for non-ferrous valves and fittings (brazed).

Tube Size,

Solenoid

Angle

Short Radius

Long Radius

 

Tee,

 

Tee,

O.D.

 

Valve

 

Valve

 

Ell

 

Ell

Line flow

Branch Flow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2

70

 

[21.3]

8.3

 

[2.5]

1.6

 

[0.5]

1.0

 

[0.3]

1.0

 

[0.3]

3.1

 

[0.9]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/8

72

 

[21.9]

10.4

 

[3.2]

1.9

 

[0.6]

1.2

 

[0.4]

1.2

 

[0.4]

3.6

 

[1.1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

75

 

[22.9]

12.5

 

[3.8]

2.1

 

[0.7]

1.4

 

[0.4]

1.4

 

[0.4]

4.2

 

[1.3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8

78

 

[23.8]

14.6

 

[4.4]

2.4

 

[0.7]

1.6

 

[0.5]

1.6

 

[0.5]

4.8

 

[1.5]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 1/8

 

 

 

18.8

 

[5.7]

3.0

 

[0.9]

2.0

 

[0.6]

2.0

 

[0.6]

6.0

 

[1.8]

1 3/8

 

 

 

22.9

 

[7.0]

3.6

 

[1.1]

2.4

 

[0.7]

2.4

 

[0.7]

7.2

 

[2.2]

1 5/8

 

 

 

27.1

 

[8.3]

4.2

 

[1.3]

2.8

 

[0.8]

2.8

 

[0.8]

8.4

 

[2.6]

2 1/8

 

 

 

35.4

 

[10.8]

5.3

 

[1.6]

3.5

 

[1.1]

3.5

 

[1.1]

10.7

 

[3.3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Image 9
Contents Heatcontroller Table of Contents Safety Information II. Introduction III. Checking Product ReceivedIV. Equipment Protection from the Environment WHY USE AN AIR Cooled Split SYSTEM? VI. Standard Unit Features 61⁄2 and 71⁄2 VII. Installation Important Message to OwnerInspection and Handling Rooftop Installation Refer to Figure Installation GeneralSlab Installation Order PartsVIII. Refrigerant Piping Data Installation of Piping Typical Piping Recommendations Refrigerant Piping Feet XI. Power Wiring VIX. Wiring Electrical PowerXII. Wire Routing XV. Leak TestingSpecification of R-410A XVI. R-410A RefrigerantQuick Reference Guide for R-410A Replacement Units XVII. Evacuation and ChargingEvaporator Coil Charging Hints XIX. Accessories ANTI-SHORT Cycle TimerXVIII. Sequence of Operation 61⁄2 and 71⁄2 TON Sight Glass / Moisture Indicator Liquid Pressure ControlLiquid Line Solenoid Valve Charge Charts XX. Miscellaneous61⁄2 TON Condenser 71⁄2 TON Condenser with 10 TON Evaporator 155 160 165High Pressure Switch HPC Maintenance and OperationLOW Pressure Switch LPC ContactorFilter Troubleshooting
Related manuals
Manual 16 pages 37.95 Kb

R-410A specifications

The Heat Controller R-410A is an advanced refrigerant used in various heating and cooling applications, particularly in residential and commercial air conditioning systems. Recognized for its efficiency and eco-friendliness, R-410A has become a popular choice among HVAC manufacturers and professionals.

One of the main features of R-410A is its high efficiency. It operates at a higher pressure than traditional refrigerants, which allows it to transfer heat more effectively. This results in improved energy efficiency ratings (SEER and EER) for systems utilizing R-410A, leading to lower energy bills and reduced environmental impact.

R-410A is also known for its environmental sustainability. Unlike its predecessor, R-22, R-410A has zero ozone depletion potential (ODP) due to its composition of hydrofluorocarbons (HFCs). Although it does have a global warming potential (GWP), the advancements in technology have made R-410A a more environmentally friendly option compared to many older refrigerants.

Developed through innovative technological advancements, R-410A systems often incorporate variable speed compressors and efficient heat exchangers. These technologies allow for better modulation of cooling and heating outputs, ensuring that the indoor environment remains comfortable while using the least amount of energy possible.

Another significant characteristic of R-410A is its compatibility with a wide range of HVAC equipment. Many new air conditioning systems are designed specifically to use R-410A, which has led to the creation of a robust market for these units. Additionally, R-410A systems tend to require less maintenance and have longer lifespans compared to those using older refrigerants.

Safety is another consideration for R-410A users. While R-410A is non-toxic and non-flammable, technicians who work with this refrigerant need to be trained and certified due to its high-pressure properties. Proper handling and installation are crucial to ensure system efficiency and reliability.

In summary, the Heat Controller R-410A stands out in the HVAC industry for its efficiency, environmental benefits, advanced technologies, and compatibility with modern systems. As the industry continues to evolve, R-410A remains a key player, paving the way towards more sustainable and efficient heating and cooling solutions.