Heat Controller REG-183A, REG-243A service manual Disassembly, Mechanical parts

Page 13

Disassembly

Disassembly

- Before the following disassembly, power switch is set to off and disconnected the power cord.

Mechanical parts

1. Front grille

1. Open the inlet grille upward or downward.

2. Remove the screw which fastens the front grille.

3. Pull the front grille from the right side.

4. Remove the front grille. (See Fig. 16)

5. Re-install the component by referring to the removal procedure.

NOTICE Mark of inlet grille means opening direction.

2. Cabinet

1. After disassembling the front grille, remove the screws which fasten the cabinet at both sides. Keep these for later use.

2. Remove the two screws which fasten the cabinet at back. (See Fig. 17)

3. Pull the base pan forward.

Figure 16

3. Control box

1. Remove the front grille. (Refer to section 1)

2. Pull the base pan forward so that you can remove the 2 screws which fasten the cover control at the right side. (See Fig. 18)

3. Remove the 3 screws which fasten the controlbox. (See Fig. 18)

4. Discharge the capacitor by placing a 20,000 ohm

 

resistor across the capacitor terminals.

Figure 17

5.Disconnect two wire housings in the control box.

6.Pull the control box forward completely.

7.Re-install the components by referring to the removal

procedure. (See Fig. 18)

(Refer to the wiring diagram found on page 29~30 in this manual and on the control box.)

Figure 18

Service Manual 14

Image 13
Contents +$7&21752//5,1& Table of Contents Installation Safety PrecautionsThere is risk or fire or electric shock Symbols Used in this Manual DimensionsOutside Dimensions Items Models Product SpecificationsHow to use the Reversible Inlet grille How to Install the unitWindow Requirements Window RequirementsSuggested tool Requirements Line marked window stool Cabinet InstallationWindow installation of room air conditioner is now Completed Ventilation OperationMechanical parts DisassemblyCover at the top Air handling partsFan Electrical partsCapacitor Synchronous Motor Condenser Refrigeration cyclePage Pulling Vacuum Wiring Diagram Schematic DiagramPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide +$7&21752//5,1&