Disassembly

6. Fan

1.

Remove the cabinet. (Refer to section 2)

 

2.

Remove the brace and shroud cover.

 

 

(Refer to section 4)

 

3.

Remove the side cover with 2 screws.(See Fig. 23)

 

4.

Remove the 5 or 6 screws which fasten the condenser.

 

5.

Move the condenser sideways carefully.

 

6.

Remove the clamp which secures the fan.

 

7.

Remove the fan. (See Fig. 23)

Figure 23

8.

Re-install the components by referring to the removal

 

procedure, above.

7.Shroud

1.Remove the fan. (Refer to section 6)

2.Remove the 2 screws which fasten the shroud.

3.Remove the shroud. (See Fig. 24)

4.Re-install the component by referring to the removal procedure, above.

Electricalparts

8.Motor

1.Remove the cabinet. (Refer to section 2)

2.Remove the cover control and disconnect a wire hous- ing in control box. (Refer to section 3)

3.Remove the blower. (Refer to section 5)

4.Remove the fan. (Refer to section 6)

5.Remove the 4 screws which fasten the motor. (See Fig. 25)

6.Remove the motor.

7.Re-install the components by referring to the removal procedure, above.

9.Compressor

1.Remove the cabinet. (Refer to section 2)

2.Discharge the refrigerant system using FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a watco a-1) before venting the FreonTM . Leave the valve in place after servicing the system.

3.Disconnect the 3 leads from the compressor.

4.After purging the unit completely, unbraze the suction and discharge tubes at the compressor connections.

5.Remove the 3 nuts and the 3 washers which fasten the compressor. (See Fig. 26)

6.Remove the compressor.

7.Re-instill the components by referring to the removal procedure, above.

Figure 24

Figure 25

Figure 26

Service Manual 16

Image 15
Contents +$7&21752//5,1& Table of Contents Installation Safety PrecautionsThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Items Models Product SpecificationsHow to use the Reversible Inlet grille How to Install the unitWindow Requirements Window RequirementsSuggested tool Requirements Line marked window stool Cabinet InstallationWindow installation of room air conditioner is now Completed Ventilation OperationMechanical parts DisassemblyCover at the top Air handling partsFan Electrical partsCapacitor Synchronous Motor Condenser Refrigeration cyclePage Pulling Vacuum Wiring Diagram Schematic DiagramPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide +$7&21752//5,1&