Heat Controller REG-243A, REG-183A service manual Capacitor

Page 16

Disassembly

10.CAPACITOR

1.Remove the control box. (Refer to section 3)

2.Remove the screw and knobs which fasten the display

panel.

3. Disconnect the 2 leads from the rocker switch and remove the panel.

4. Remove a screw and unfold the control box. (See Fig. 27)

5. Remove the screw and the clamp which fastens the capacitor. (See Fig. 27)

6. Disconnect all the leads of capacitor terminals.

7. Re-install the components by referring to the removal procedure, above.

Figure 27

11. POWER CORD

1. Remove the control box. (Refer to section 3)

2. Unfold the control box. (Refer to section 10)

3. Disconnect the grounding screw from the control box.

4. Disconnect 2 receptacles.

5. Remove a screw which fastens the clip cord.

6. Pull the power cord. (See Fig. 28)

7. Re-install the component by referring to the removal procedure, above.

(Use only one ground-marked hole for ground connec-

tion.)

Figure 28

 

8.If the supply cord of this appliance is damaged, it must be replaced by the special cord.

(The special cord means the cord which has the same specification marked on the supply cord fitted to the unit.)

12. THERMISTOR

1. Remove the control box. (Refer to section 3)

2. Unfold the control box. (Refer to section 10)

3. Disconnect the thermistor terminals from main P.W.B assembly.

4. Remove the thermistor.

5. Re-install the components by referring to the removal procedure above. (See Figure 30)

Figure 29

17Room Air Conditioner

Image 16
Contents +$7&21752//5,1& Table of Contents Safety Precautions InstallationThere is risk or fire or electric shock Symbols Used in this Manual DimensionsOutside Dimensions Product Specifications Items ModelsHow to Install the unit How to use the Reversible Inlet grilleWindow Requirements Window RequirementsSuggested tool Requirements Cabinet Installation Line marked window stoolWindow installation of room air conditioner is now Completed Operation Ventilation Disassembly Mechanical partsAir handling parts Cover at the topElectrical parts FanCapacitor Synchronous Motor Refrigeration cycle CondenserPage Pulling Vacuum Schematic Diagram Wiring DiagramTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide +$7&21752//5,1&