Heat Controller REG-243A, REG-183A service manual Product Specifications, Items Models

Page 6

Specfications

Product Specifications

ITEMS

 

MODELS

 

 

POWER SUPPLY

 

COOLING CAPACITY

(Btu/h)

INPUT

 

(W)

RUNNING CURRENT

(A)

E.E.R

 

(BTU/W.h)

HEATING CAPACITY

(Btu/h)

INPUT

 

(W)

RUNNING CURRENT

(A)

 

COOLING

INDOOR(°C)

OPERATING

OUTDOOR(°C)

 

CONDITION

HEATING

INDOOR(°C)

 

OUTDOOR(°C)

 

 

REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER

FAN, INDOOR FAN, OUTDOOR

FAN SPEEDS, FAN/COOLING/HEATING FAN MOTOR

OPERATION CONTROL

ROOM TEMP. CONTROL

AIR DIRECTION CONTROL

CONSTRUCTION ELECTRIC HEATER

COMPRESSOR

PROTECTOR FAN MOTOR ELECTRIC HEATER

POWER CORD

 

DRAIN SYSTEM

 

NET WEIGHT

(lbs/kg)

OUTSIDE DIMENSION

(inch)

(W x H x D)

(mm)

REG-183A

REG-243A

1Ø, 208/230V, 60Hz

1Ø, 208/230V, 60Hz

17,500/17,000

23,00/23,500

1,800/1,750

2,700/2,760

8.2/8.8

13.2/12.2

9.7/9.7

8.5/8.5

11,600/9,400

9,400/11,600

3,100/3,670

3,750/3,770

15.0/16.0

15.0/16.0

26.7 (DB)*

19.4 (WB)**

35 (DB)*

23.9 (WB)**

21.1 (DB)*

15.6 (DB)**

8.3 (DB)*

6.1 (DB)**

810(28.6oz)

1040(36.7oz)

3ROW 18STACKS

3ROW 15STACKS

2ROW 19STACKS,L-BENDING TYPE

2ROW 16STACKS,L-BENDING TYPE

BLOWER

PROPELLER TYPE FAN WITH SLINGER-RING

1 / 2 / 2

1 / 2 / 2

6POLES TOUCH PANEL THERMISTOR

VERTICAL LOUVER(RIGHT&LEFT)

HORIZONTAL LOUVER(UP&DOWN)

SLIDE IN-OUT CHASSIS

3.5KW, 230V

INTERNAL OVERLOAD PROTECTOR

INTERNAL THERMAL PROTECTOR

FUSE LINK, BIMETAL THERMOSTAT

1.6m(3 WIRE WITH GROUNDING)

ATTACHMENT PLUG(CORD-CONNECTED TYPE) DRAIN PIPE OR SPLASHED BY FAN SLINGER

137/62

146/66

26 X 16 27/32 X 30 5/16

26 X 16 27/32 X 30 5/16

660 X 428 X 770

660 X 428 X 770

* DB:Dry Bulb **WB:Wet Bulb

NOTE: Please refer to Label Quality on the produst since this specification may be changed for improving performance.

6Room Air Conditioner

Image 6
Contents +$7&21752//5,1& Table of Contents Safety Precautions InstallationThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications Items ModelsHow to Install the unit How to use the Reversible Inlet grilleWindow Requirements Window RequirementsSuggested tool Requirements Cabinet Installation Line marked window stoolWindow installation of room air conditioner is now Completed Operation VentilationDisassembly Mechanical partsAir handling parts Cover at the topElectrical parts FanCapacitor Synchronous Motor Refrigeration cycle CondenserPage Pulling Vacuum Schematic Diagram Wiring DiagramTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide +$7&21752//5,1&
Related manuals