Heat Controller RAH-123G TroubleshootingBeforeCallingService, When Service Is Required

Page 15

Heat Controller, Inc.

Room Air Heat Pump with R-410A

Owner’s Manual

 

 

 

WARNING

TroubleshootingBeforeCallingService

The following is a list of problems that are sometimes encountered when using a room air conditioner. Possible cause and suggested remedies are given for each problem.

If the problem cannot be fixed using the suggested remedies, see WHEN SERVICE IS REQUIRED section.

PROBLEM

POSSIBLE CAUSE

SUGGESTED REMEDY

UNIT WILL NOT RUN

No power to unit

Push reset button on power cord.

 

 

Set Fan Control to any position other than OFF.

 

 

Make sure plug is firmly seated in outlet.

 

 

Check for blown fuses, tripped circuit breakers.

 

 

 

LITTLE OR NO COOLING

 

 

LITTLE OR NO HEATING

Obstructed indoor or outdoor airflow

Remove obstruction from indoor grille or outdoor louvers.

(fan and compressor run)

dirty air filters

dirty air filter. Clean or replace, as needed.

 

 

Unit undersized for application

Check with dealer to determine proper capacity unit for application.

LITTLE OR NO COOLING

Temperature Control not set properly

For cooling, turn Temperature Control to cooler setting.

LITTLE OR NO HEATING

 

For heating, turn Temperature Control to warmer setting.

(only fan runs)

 

 

NOISY UNIT

Front panel may be loose

Tighten any loose parts.

 

Weak building construction

Provide additional support for unit.

 

Water hitting fan blade

Normal in high humidity. Stop noise by removing drain plug or

 

 

adding condensate drain cup.

 

Unit oversized for application:

Check with dealer to determine proper capacity unit for application.

 

compressor cycles on and off frequently

 

MOUNTING SUPPORT NOT

Storm window frame installed in window

Some models require removal of storm window frame before

INSTALLEd

 

installation.

FROST ON INdOOR COIL

dirty air filter

Clean air filter by vacuuming or washing with water and mild soap.

 

Normal for low outdoor temperatures

Turning Temperature Control to warmer setting reduces occurrence

 

 

and duration of frost.

FROST ON OUTdOOR COIL

Normal for outdoor temperatures at or

Call for service only if unit does not heat room and you have

(heat pump models only)

below 45°F

checked all problems and remedies listed under LITTLE OR NO

 

 

HEATING.

OdORS IN COOLING

Mold, mildew, or algae formation on wet

To reduce algae growth, use algaecide tablet in base pan; remove

 

surfaces

drain plug; add condensate drain cup and hose. Thoroughly clean

 

 

unit.

OdORS IN HEATING

Normal for first time electric heater is

Caused by dust accumulation during unused months.

 

used each season

Odor dissipates quickly with heater use.

 

 

 

 

 

When Service Is Required

Your room air conditioner dealer can give you the name of Call 866-557-1865 for service and warranty. Help them your nearest Authorized Service Center. Help them give giveyou promptyou promptserviceserviceby providing:by providing:

An accurate description of problem.

Compllete model,andserial,serialandnumbermanufacturingfrom (P) num- serialb rs fromplateserial plate.

Proof of purchase (sales receipt) upon request. Repair by unauthorized servicer that results in subsequent failure of unit voids warranty. Warranty details are con- tained in warranty certificate enclosed with unit.

Keep accurate records of service calls, including what was done, servicer’s name, and date of service.

AnyQuestions?

Most questions can be answered by your local dealer. If you have other matters that cannot be resolved locally, or you need additional information regarding other heating and cooling products offered by us - please call:

CONSUMERHeat INFORMAController,TIONIncLINE.

Customer or Technical Service Department

Tel: (86-756) 8617555 (Customer Service Center)

517-787-2100

Web Site: http://www.gree.com.cn

14

Image 15
Contents Room Air Heat Pump With R-410A Introduction SafetyInformationUnpacking ElectricalRequirementsGroundingInstructions Installation NormalCareandMaintenanceRoomHeatPumps Front Grille and Filter Removal Air Filter CleaningFront Grille and Cabinet Cleaning Fan Motor CareThrough-the-wall installation Tools NeededParts supplied on some models Electrical Requirements Window installationPower Supply Cord To test your power supply cordRecommended grounding method Attach Top Channel Remove packaging materialsBottom View Install Cabinet into WindowAttach Side Curtains Back ViewComplete Window Installation Attach Side Curtains to Window FrameFront View Top View GeneralOperatingInstructions Operating ControlsFor Electronic units To cancel the timer, press theTimer 0.5-24hr pad How to setTroubleshootingBeforeCallingService When Service Is RequiredAnyQuestions? 07/2010 66129904948

RAH-123G specifications

The Heat Controller RAH-123G stands out in the realm of climate control solutions, offering advanced features and technologies that enhance comfort while prioritizing energy efficiency. As a split system air conditioner, the RAH-123G is specifically designed to provide both heating and cooling functions, making it a versatile choice for year-round usage.

One of the main features of the RAH-123G is its impressive energy efficiency rating. With a high SEER (Seasonal Energy Efficiency Ratio) rating, this model ensures that users can enjoy consistent temperature regulation without the worry of skyrocketing energy bills. The energy-saving design not only benefits the environment but also provides long-term savings for homeowners.

The unit employs state-of-the-art inverter technology, allowing for variable speed operation. This means that the compressor adjusts its speed according to the desired temperature, leading to smoother airflow and enhanced comfort levels. The inverter technology also minimizes noise, making the RAH-123G one of the quieter options available on the market, which is ideal for bedrooms and living spaces.

Another notable characteristic of the RAH-123G is its advanced filter system, which effectively captures dust, allergens, and other airborne particles. This is particularly important for households with allergy sufferers, as it ensures the air quality is not compromised. The filters are easy to access and clean, promoting regular maintenance and longevity of the unit.

Additionally, the RAH-123G comes equipped with smart technology, allowing it to be controlled via a user-friendly app on smartphones or tablets. This feature provides the convenience of monitoring and adjusting settings remotely, ensuring that your home is at the perfect temperature before you even arrive.

The sleek and modern design of the RAH-123G complements any interior decor, making it an aesthetically pleasing addition to any home. Installation is straightforward, and the unit is built with durability in mind, ensuring it will perform reliably for years to come.

In summary, the Heat Controller RAH-123G is a formidable contender in the arena of heating and cooling solutions. Its combination of energy efficiency, advanced inverter technology, superior air filtration, and smart home integration makes it an excellent investment for those looking to enhance their home comfort. Whether battling the heat of summer or the chill of winter, the RAH-123G is equipped to maintain the ideal climate all year round.