While operation of all units is similar, controls vary slightly from model to model. Operating Controls section shows control panel of unit purchased and gives detailed information about operation of controls.

To install, remove the unit chassis from the outer case. Insert the condensate drain cup through the recessed ½” hole on the back center of the outer case. Once inserted, place a ½” diameter hose or tube on the drain cup bottom spout. The hose allows you to route where you want the excess water to go. Reinsert the unit chassis into the outer case. The unit basepan overflow hole will be positioned directly above the drain cup and will catch any water that might run out.

Airflow Around Unit

 

 

 

Select the highest fan speed and set temperature control to

 

 

 

its coldest position. When the desired temperature is

 

 

 

reached, slowly move the temperature control toward a

 

 

 

warmer setting until the compressor shuts off. The thermo-

 

 

 

stat will then cycle the compressor on and off to maintain this

 

 

Outer Case

selected temperature. Adjust the fan speed for desired air

 

 

 

circulation.

Condensate

 

 

 

 

 

 

 

 

 

 

 

 

drain Cup

 

 

 

 

 

 

+

 

 

BAFFLES

 

1/2" diameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

 

 

 

 

 

 

Hose

OUTdOOR

 

 

 

 

 

 

 

 

 

 

 

Switchover Thermostat Control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOUVERS

 

 

 

 

 

 

 

 

 

 

 

Emergency heat switch overrides heat pump (compressor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and starts auxiliary electrical heater. When switch is ON,

 

 

 

 

 

 

 

 

 

 

Indoo

r

 

 

 

 

 

 

 

 

 

 

heat pump is locked out.

 

 

 

 

 

 

 

 

 

 

Grille

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Changing Airflow Direction Baffles

• Use emergency switch only when heat pump fails to

provide adequate heat. Cause of heat pump malfunc-

Airflow on unit may be diverted left or right from center by

tion should be determined by authorized servicer. Cost

baffles. Upward and downward air discharge is provided by

of operating unit will increase when emergency heat

tilting louvers. Adjust baffles and tilt louvers for desired

switch is engaged.

airflow pattern.

Only for Qualified Service Personnel

 

 

 

 

 

 

 

 

 

 

 

 

Airflow Around Unit

Check the indoor grille and outdoor louvers for obstructions to airflow. do not block the airflow to and from the unit. If air is obstructed and/or deflected back into the unit, the air conditioner’s compressor may cycle on and off rapidly. This could damage your unit.

Drain Cup Installation and Use

Your air conditioner uses a system where the water removed from the indoor air (condensate) is channeled to the outdoor side of the unit. The outdoor fan blade has a “slinger” ring attached to it that dips into the water and slings the water onto the outdoor coil surface. This is the sound of water you hear during normal operation. The water quickly evaporates on this warm surface and improves the efficiency of your air conditioner. In normal conditions the unit can evaporate the water as fast as it is removed from the indoor air.

However, in very humid conditions excess amounts of water may drip off the unit chassis. If this proves to be a problem, install the condensate drain cup included with the unit to route excess water where it would not be a problem (see illustration).

To access and engage emergency switch:

• Unplug unit.

1.Remove front grille, air filter, and plastic front, as described in Installation Instructions.

2.Slide chassis out of case about two inches.

3.Locate access hole for emergency switch above label on right front of control box.

4.Remove control panel for access.

5.Remove outdoor thermostat from control box and locate "flat head" adjustment screw on back of thermostat.

6.To start emergency heat, insert flathead screwdriver into slot and turn counterclockwise until switch-stop is reached.

7.Return chassis to case.

8.Re-install lthermostat and mount control panel door.

9.Replace plastic front, air filter, and front

grille.

11

Image 12
Contents Room Air Heat Pump With R-410A SafetyInformation IntroductionUnpacking ElectricalRequirementsGroundingInstructions Installation NormalCareandMaintenanceRoomHeatPumps Air Filter Cleaning Front Grille and Cabinet CleaningFan Motor Care Front Grille and Filter RemovalThrough-the-wall installation Tools NeededParts supplied on some models Window installation Electrical RequirementsPower Supply Cord To test your power supply cordRecommended grounding method Remove packaging materials Attach Top ChannelInstall Cabinet into Window Attach Side CurtainsBack View Bottom ViewComplete Window Installation Attach Side Curtains to Window FrameFront View Top View GeneralOperatingInstructions Operating ControlsFor Electronic units How to set To cancel the timer, press theTimer 0.5-24hr padTroubleshootingBeforeCallingService When Service Is RequiredAnyQuestions? 07/2010 66129904948

RAH-123G specifications

The Heat Controller RAH-123G stands out in the realm of climate control solutions, offering advanced features and technologies that enhance comfort while prioritizing energy efficiency. As a split system air conditioner, the RAH-123G is specifically designed to provide both heating and cooling functions, making it a versatile choice for year-round usage.

One of the main features of the RAH-123G is its impressive energy efficiency rating. With a high SEER (Seasonal Energy Efficiency Ratio) rating, this model ensures that users can enjoy consistent temperature regulation without the worry of skyrocketing energy bills. The energy-saving design not only benefits the environment but also provides long-term savings for homeowners.

The unit employs state-of-the-art inverter technology, allowing for variable speed operation. This means that the compressor adjusts its speed according to the desired temperature, leading to smoother airflow and enhanced comfort levels. The inverter technology also minimizes noise, making the RAH-123G one of the quieter options available on the market, which is ideal for bedrooms and living spaces.

Another notable characteristic of the RAH-123G is its advanced filter system, which effectively captures dust, allergens, and other airborne particles. This is particularly important for households with allergy sufferers, as it ensures the air quality is not compromised. The filters are easy to access and clean, promoting regular maintenance and longevity of the unit.

Additionally, the RAH-123G comes equipped with smart technology, allowing it to be controlled via a user-friendly app on smartphones or tablets. This feature provides the convenience of monitoring and adjusting settings remotely, ensuring that your home is at the perfect temperature before you even arrive.

The sleek and modern design of the RAH-123G complements any interior decor, making it an aesthetically pleasing addition to any home. Installation is straightforward, and the unit is built with durability in mind, ensuring it will perform reliably for years to come.

In summary, the Heat Controller RAH-123G is a formidable contender in the arena of heating and cooling solutions. Its combination of energy efficiency, advanced inverter technology, superior air filtration, and smart home integration makes it an excellent investment for those looking to enhance their home comfort. Whether battling the heat of summer or the chill of winter, the RAH-123G is equipped to maintain the ideal climate all year round.