Heat Controller RAH-123G owner manual How to set, To cancel the timer, press theTimer 0.5-24hr pad

Page 14
0.5-24HR
TIMER

Owner’s Manual

Room Air Heat Pump with R-410A

Heat Controller, Inc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer/DelayOFF—WhenOFF—theWhenair condthe airconditioneris on, is on, it can be set to automatically turn off in 0.5

to 24 hours.

How to set:

Press theTimer 0.5 –24hrpad on the unit or

the

TIMER

pad on the remote control. Each

0.5-24HR DELAY

touch of the Increase / Decrease pads on the unit or the Increase + / Decrease pads on

the remote control will set the timer in

0.5hour or 1hour intervals(the intervals is

0.5hour as the delay timer below 10 hours;

the intervals is 1 hour as the delay timer above 10 hours) The Set light will turn on

while setting.

To review the remaining time on the Timer

0.5 –24hrtimer, press theTimer 0.5–24hrpad on the

unit or the DELAY pad on the remote control.

Use the Increase / Decrease pads on the unit or the Increase + / Decrease pads on the

remote control to set a new time if desired.

To cancel the timer, press theTimer 0.5–24hr pad

until the light on the Timer 0.5–24hrpad goes off.

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 20 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

Make sure batteries are fresh and installed correctly as indicated on the remote control.

Cool Mode

Use the Cool mode at Low, Med, High or Auto Fan Speed for cooling. Use the Temperature Increase /Decrease pads to set the desired temperature between 61°F and 86°F in 1°F increments.

The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on

while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes

for the compressor to start and cooling to begin.

This time delay is required to protect the compressor.

Cooling Descriptions

For Normal Cooling—Select the Cool mode and High or Med fan with a middle set temperature.

For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.

For Quieter & Nighttime Cooling—Select the Cool mode and Low fan with a middle set

temperature.

Energy Saver Mode

Controls the fan.

ON—The fan will cycle on and off with the compressor. This results in wider variations of room temperature and humidity. Normally used

when the room is unoccupied. NOTE: The fan may continue to run for a short time after the compressor cycles off.

OFF—The fan runs all the time, while the compressor cycles on and off.

Fan Only Mode

Use the Fan Only Mode at Low, Med or High fan speed to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.

Heat Mode (On some models)

Use the Heat mode at Low, Med, High or Auto Fan Speed for heating. Use the Temperature Increase /Decrease pads to set the desired temperature between 61°F and 86°F in 1°F increments.

Auto Fan Speed

Set to Auto fan speed for the fan speed to auto- matically set to the speed needed to provide opti- mum comfort settings with the set temperature. If the room needs more cooling, the fan speed will automatically increase. If the room needs less cooling, the fan speed will automatically decrease.

NOTE: Auto Fan Speed cannot be used when in the Fan Only Mode.

Power Outage Recovery Feature

In the case of a power outage or interruption, the

unit will automatically re-start in the settings last used after the power is restored. If the Timer/Delay0.5-24hr

feature was set, it will resume countdown. You may need to set a new time if desired.

13

Image 14
Contents Room Air Heat Pump With R-410A SafetyInformation IntroductionGroundingInstructions UnpackingElectricalRequirements RoomHeatPumps InstallationNormalCareandMaintenance Fan Motor Care Air Filter CleaningFront Grille and Cabinet Cleaning Front Grille and Filter RemovalParts supplied on some models Through-the-wall installationTools Needed Window installation Electrical RequirementsRecommended grounding method Power Supply CordTo test your power supply cord Remove packaging materials Attach Top ChannelBack View Install Cabinet into WindowAttach Side Curtains Bottom ViewFront View Top View Complete Window InstallationAttach Side Curtains to Window Frame GeneralOperatingInstructions Operating ControlsFor Electronic units How to set To cancel the timer, press theTimer 0.5-24hr padAnyQuestions? TroubleshootingBeforeCallingServiceWhen Service Is Required 07/2010 66129904948

RAH-123G specifications

The Heat Controller RAH-123G stands out in the realm of climate control solutions, offering advanced features and technologies that enhance comfort while prioritizing energy efficiency. As a split system air conditioner, the RAH-123G is specifically designed to provide both heating and cooling functions, making it a versatile choice for year-round usage.

One of the main features of the RAH-123G is its impressive energy efficiency rating. With a high SEER (Seasonal Energy Efficiency Ratio) rating, this model ensures that users can enjoy consistent temperature regulation without the worry of skyrocketing energy bills. The energy-saving design not only benefits the environment but also provides long-term savings for homeowners.

The unit employs state-of-the-art inverter technology, allowing for variable speed operation. This means that the compressor adjusts its speed according to the desired temperature, leading to smoother airflow and enhanced comfort levels. The inverter technology also minimizes noise, making the RAH-123G one of the quieter options available on the market, which is ideal for bedrooms and living spaces.

Another notable characteristic of the RAH-123G is its advanced filter system, which effectively captures dust, allergens, and other airborne particles. This is particularly important for households with allergy sufferers, as it ensures the air quality is not compromised. The filters are easy to access and clean, promoting regular maintenance and longevity of the unit.

Additionally, the RAH-123G comes equipped with smart technology, allowing it to be controlled via a user-friendly app on smartphones or tablets. This feature provides the convenience of monitoring and adjusting settings remotely, ensuring that your home is at the perfect temperature before you even arrive.

The sleek and modern design of the RAH-123G complements any interior decor, making it an aesthetically pleasing addition to any home. Installation is straightforward, and the unit is built with durability in mind, ensuring it will perform reliably for years to come.

In summary, the Heat Controller RAH-123G is a formidable contender in the arena of heating and cooling solutions. Its combination of energy efficiency, advanced inverter technology, superior air filtration, and smart home integration makes it an excellent investment for those looking to enhance their home comfort. Whether battling the heat of summer or the chill of winter, the RAH-123G is equipped to maintain the ideal climate all year round.