Heat Controller RAH-123G owner manual Electrical Requirements, Window installation

Page 7

Heat Controller, Inc.

Room Air Heat Pump with R-410A

Owner’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window installation

Window opening measurements:

27" min. to 39" max. opening width.

16¹⁄₄" min. opening height.

A

B

A. 27" min.

B. 16¹⁄₄" min.

Through-the-wall installation

The wall opening measurements should be:

Height: 16" plus twice the thickness of wood used to build frame.

Width: 22⁵⁄₈" plus twice the thickness of wood used to build frame.

C

A

B

C

A.16"

B. 22⁵⁄₈"

C. Wood thickness

Electrical Requirements

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel on the flange below the control panel area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply

 

 

cord

Wiring requirements

 

 

115-volt (103.5 min. - 126.5 max.)

 

 

0-12 amps

 

 

15-amp time-delay fuse or circuit breaker

 

 

Use on single outlet circuit only.

 

 

 

¹⁄₄"

230-volt (207 min. - 253 max.)

 

0-12 amps

(0.6 cm)

 

 

15-amp time-delay fuse or circuit breaker

 

 

 

 

 

 

Use on single outlet circuit only.

 

 

 

 

 

 

208/230-volt (198min. - 253 max.)

 

 

0-16 amps

 

 

20-amp time-delay fuse or circuit breaker

 

 

Use on single outlet circuit only.

 

 

 

¹⁄₂"

230-volt (207 min. - 253 max.)

 

0-24 amps

(1.3 cm)

30-amp time-delay fuse or circuit breaker Use on single outlet circuit only.

6

Image 7
Contents Room Air Heat Pump With R-410A Introduction SafetyInformationElectricalRequirements UnpackingGroundingInstructions NormalCareandMaintenance InstallationRoomHeatPumps Front Grille and Filter Removal Air Filter CleaningFront Grille and Cabinet Cleaning Fan Motor CareTools Needed Through-the-wall installationParts supplied on some models Electrical Requirements Window installationTo test your power supply cord Power Supply CordRecommended grounding method Attach Top Channel Remove packaging materialsBottom View Install Cabinet into WindowAttach Side Curtains Back ViewAttach Side Curtains to Window Frame Complete Window InstallationFront View Top View GeneralOperatingInstructions Operating ControlsFor Electronic units To cancel the timer, press theTimer 0.5-24hr pad How to setWhen Service Is Required TroubleshootingBeforeCallingServiceAnyQuestions? 07/2010 66129904948

RAH-123G specifications

The Heat Controller RAH-123G stands out in the realm of climate control solutions, offering advanced features and technologies that enhance comfort while prioritizing energy efficiency. As a split system air conditioner, the RAH-123G is specifically designed to provide both heating and cooling functions, making it a versatile choice for year-round usage.

One of the main features of the RAH-123G is its impressive energy efficiency rating. With a high SEER (Seasonal Energy Efficiency Ratio) rating, this model ensures that users can enjoy consistent temperature regulation without the worry of skyrocketing energy bills. The energy-saving design not only benefits the environment but also provides long-term savings for homeowners.

The unit employs state-of-the-art inverter technology, allowing for variable speed operation. This means that the compressor adjusts its speed according to the desired temperature, leading to smoother airflow and enhanced comfort levels. The inverter technology also minimizes noise, making the RAH-123G one of the quieter options available on the market, which is ideal for bedrooms and living spaces.

Another notable characteristic of the RAH-123G is its advanced filter system, which effectively captures dust, allergens, and other airborne particles. This is particularly important for households with allergy sufferers, as it ensures the air quality is not compromised. The filters are easy to access and clean, promoting regular maintenance and longevity of the unit.

Additionally, the RAH-123G comes equipped with smart technology, allowing it to be controlled via a user-friendly app on smartphones or tablets. This feature provides the convenience of monitoring and adjusting settings remotely, ensuring that your home is at the perfect temperature before you even arrive.

The sleek and modern design of the RAH-123G complements any interior decor, making it an aesthetically pleasing addition to any home. Installation is straightforward, and the unit is built with durability in mind, ensuring it will perform reliably for years to come.

In summary, the Heat Controller RAH-123G is a formidable contender in the arena of heating and cooling solutions. Its combination of energy efficiency, advanced inverter technology, superior air filtration, and smart home integration makes it an excellent investment for those looking to enhance their home comfort. Whether battling the heat of summer or the chill of winter, the RAH-123G is equipped to maintain the ideal climate all year round.