1. Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,

WARNING

 

and

CAUTION

, those points which are related to the strong possibility of an

installation done

in

error resulting in death or serious injury are listed in the

WARNING

section. However, there is

also a possibility of serious consequences in relationship to the points listed in the CAUTION section as well. In either case, important safety related information is indicated, so by all means,

properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

15

Image 16
Contents Duct Type AIR Conditioning Table of Contents Disposal of the old air conditioner Safety Precautions Bodily injury could result by a collapseDo not operate the system while Applicable ambient temperature range Machine is adaptive in following situationParts and Functions Malfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientFollowings are not malfunction Shuru ShuruCare and Maintenance Points to observeWhen heating is started HOT KEEPis operated in the following casesInstallation Manual for Outdoor Unit Installation placeInstallation Installation where the area with strong windsOpen space requirement around the unit Precautions for refrigerant piping Outline pipingPiping size Piping connectionPurging method the refrigerant is R407C To use vacuum pumpInstallation Manual for Indoor Unit Avoid installation and use at those places listed below Preparation of indoor unitFigure of installation dimension unit mm Preparation for suspending the unitWood structure Install the hoisting screwNew cement panel Original cement panel Steel structureSuspending of indoor unit RequirementsPermitted length and fall of connection pipe Confirm drainageConnection of refrigerant pipe Perform with two spanners Installation Manual for Electric Wiring Electric wiringInstallation Manual for Wire Controller Check and Test RUN Set of the air sending of the fan motor

HDU-12HA03/M(R1)(B), HDU-09HA03/M(R1)(B), AD092AMBHA, AD122AMBHA, AU122AABHA specifications

Haier, a global leader in home appliances, has consistently pushed the boundaries of innovation and efficiency in air conditioning systems. Among its impressive lineup are the Haier HDU-09HA03/M(R1)(B), HDU-12HA03/M(R1)(B), AD092AMBHA, AU092AABHA, and AD122AMBHA models. These air conditioning units not only offer comfort but also incorporate advanced technologies and characteristics that enhance user experience.

The Haier HDU-09HA03/M(R1)(B) and HDU-12HA03/M(R1)(B) are split air conditioning systems known for their efficient cooling and heating capabilities. They feature high energy efficiency ratings thanks to their inverter technology, which adjusts the compressor's speed based on the cooling demand, resulting in lower power consumption and cost savings. The units are designed with a sleek and modern aesthetic, making them a perfect fit for various interior decors.

The AD092AMBHA and AU092AABHA models stand out for their compact design and powerful performance. These systems are equipped with smart features like Wi-Fi connectivity, allowing users to control their air conditioning remotely via a mobile app. This feature provides convenience and flexibility, enabling users to adjust settings before arriving home. Additionally, these models boast self-cleaning functions and advanced filtration systems that enhance indoor air quality by removing dust and allergens.

The AD122AMBHA model is designed for larger spaces, offering robust cooling and heating efficiency. It employs a high-performance compressor and enhanced airflow technology, ensuring consistent temperature control. Furthermore, its operation is quiet, making it an ideal choice for residential and commercial environments where noise can be a concern.

All these Haier models share a commitment to sustainability and environmental responsibility. They utilize eco-friendly refrigerants that minimize ozone depletion and are compliant with the latest environmental regulations. Moreover, the energy efficiency of these units significantly lowers carbon emissions, aligning with global efforts toward sustainability.

In summary, Haier's HDU-09HA03/M(R1)(B), HDU-12HA03/M(R1)(B), AD092AMBHA, AU092AABHA, and AD122AMBHA air conditioning models are exemplary products that combine cutting-edge technology, energy efficiency, and user convenience. With features like inverter technology, Wi-Fi control, and enhanced air quality functions, these models cater to diverse consumer needs while contributing to a more sustainable future.