SAFETY PRECAUTIONS

Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system. Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown in the column of

" WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions

are shown in the column of "CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety.

Symbols which appear frequently in the text have following meanings.

Strictly prohibited.

Observe instructions faithfully.

Provide a positive grounding.

When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.

CAUTIONS FOR INSTALLATION

The system should be applied to places as office, restaurant, residence and the like.

Application to inferior environment such as an engi- neering shop, could cause equipment malfunction and serious injury or death.

WARNING

The system should be installed by your dealer or a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

When you need some optional devices such as a hu- midifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

CAUTION

Do not install nearby the place where may

Depending on the place of installation, a

Drain pipe should be arranged to provide a

have leakage of flammable gas.

circuit breaker may be necessary.

positive draining.

 

ON

 

 

OFF

 

If the gas leakes and gathers around, it may cause

Unless the circuit breaker is installed, it could

If the pipe is arranged improperly, furniture or the

the fire.

cause elecrical shocks.

likes may be damaged by leaked water.

Where strong winds may prevail, the system should be fixed securely to prevent a collapse.

Install on the place where can endure the weight of air conditioner.

Make sure the system is grounded.

Bodily injury could result by a collapse.

Bodily injury could result by a careless installation.

CAUTIONS FOR OPERATION

WARNING

Grounding cable should never be connected to a gas pipe, city water pipe, lightning conductor rod or grounding cable of telephone. If the grounding cable is not set properly, it could cause electric shocks.

You should refrain from exposing your body

Do not poke the air inlet or outlet with a

When any abnormal condition (scorching smell or oth-

directly to cool wind for a long time.

bar, etc.

ers) is found, stop the operation immediately and turn

 

 

off the power switch. Then consult your dealer.

It could affect your physical condition or cause some health problems.

Since the internal fan is operating with a high speed, it could cause an injury.

If you continue the operation without removing the cause, it could result in a trouble, electric shock or fire.

CAUTION

The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, pre- cision deices or work of art.

Do not handle switches with a wet hand.

Combustion apparatus should not be placed allowing a direct exposure to wind of air con- ditioner.

It could cause deterioration of food or other problems.

It could cause electric shocks.

Incomplete combustion could occur on the apparatus.

3

Image 4
Contents Duct Type AIR Conditioning Table of Contents Disposal of the old air conditioner Safety Precautions Bodily injury could result by a collapseDo not operate the system while Applicable ambient temperature range Machine is adaptive in following situationParts and Functions Malfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientFollowings are not malfunction Shuru ShuruCare and Maintenance Points to observeWhen heating is started HOT KEEPis operated in the following casesInstallation Manual for Outdoor Unit Installation placeInstallation Installation where the area with strong windsOpen space requirement around the unit Precautions for refrigerant piping Outline pipingPiping size Piping connectionPurging method the refrigerant is R407C To use vacuum pumpInstallation Manual for Indoor Unit Avoid installation and use at those places listed below Preparation of indoor unitFigure of installation dimension unit mm Preparation for suspending the unitWood structure Install the hoisting screwNew cement panel Original cement panel Steel structureSuspending of indoor unit RequirementsPermitted length and fall of connection pipe Confirm drainageConnection of refrigerant pipe Perform with two spanners Installation Manual for Electric Wiring Electric wiringInstallation Manual for Wire Controller Check and Test RUN Set of the air sending of the fan motor

HDU-12HA03/M(R1)(B), HDU-09HA03/M(R1)(B), AD092AMBHA, AD122AMBHA, AU122AABHA specifications

Haier, a global leader in home appliances, has consistently pushed the boundaries of innovation and efficiency in air conditioning systems. Among its impressive lineup are the Haier HDU-09HA03/M(R1)(B), HDU-12HA03/M(R1)(B), AD092AMBHA, AU092AABHA, and AD122AMBHA models. These air conditioning units not only offer comfort but also incorporate advanced technologies and characteristics that enhance user experience.

The Haier HDU-09HA03/M(R1)(B) and HDU-12HA03/M(R1)(B) are split air conditioning systems known for their efficient cooling and heating capabilities. They feature high energy efficiency ratings thanks to their inverter technology, which adjusts the compressor's speed based on the cooling demand, resulting in lower power consumption and cost savings. The units are designed with a sleek and modern aesthetic, making them a perfect fit for various interior decors.

The AD092AMBHA and AU092AABHA models stand out for their compact design and powerful performance. These systems are equipped with smart features like Wi-Fi connectivity, allowing users to control their air conditioning remotely via a mobile app. This feature provides convenience and flexibility, enabling users to adjust settings before arriving home. Additionally, these models boast self-cleaning functions and advanced filtration systems that enhance indoor air quality by removing dust and allergens.

The AD122AMBHA model is designed for larger spaces, offering robust cooling and heating efficiency. It employs a high-performance compressor and enhanced airflow technology, ensuring consistent temperature control. Furthermore, its operation is quiet, making it an ideal choice for residential and commercial environments where noise can be a concern.

All these Haier models share a commitment to sustainability and environmental responsibility. They utilize eco-friendly refrigerants that minimize ozone depletion and are compliant with the latest environmental regulations. Moreover, the energy efficiency of these units significantly lowers carbon emissions, aligning with global efforts toward sustainability.

In summary, Haier's HDU-09HA03/M(R1)(B), HDU-12HA03/M(R1)(B), AD092AMBHA, AU092AABHA, and AD122AMBHA air conditioning models are exemplary products that combine cutting-edge technology, energy efficiency, and user convenience. With features like inverter technology, Wi-Fi control, and enhanced air quality functions, these models cater to diverse consumer needs while contributing to a more sustainable future.