Haier AD182AMBEA(ECO), AD42NAMBEA(ECO) Malfunction, The followings are not malfunction

Page 9
The followings are not malfunction

Manual background Malfunction

The followings are not malfunction

Water flowing sound is heard.

Shuru Shuru

When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.

Cracking sound is heard.

This is caused by heat expansion or contraction of plastics.

 

It smells.

Air which blows out from the indoor unit sometimes smells.

 

 

The smell results from residents of tobacco smoke or cosmetics

 

stuck inside of unit.

 

During operation,

When the air conditioner is used at restaurant etc. where dense

white fog comes

edible oil fume is always exists, white fog sometimes blows out

out of indoor unit.

of air outlet during operation.

 

 

In this case consult sales dealer for cleaning the heat exchanger.

It is switched into the FAN mode

To prevent frost from being accumulated on the indoor unit heat

during cooling.

exchanger, it is sometimes automatically switched to the FAN mode

 

but it will soon return to the cooling mode.

 

The air conditioner can not be

Even if the operation switch is turned on, cooling, dehumidifying

restarted soon after it stops.

or heating is not operable for three minutes after the conditioner is

Unit does

stopped. Because the protecting circuit is activated.

Wait for

(During this time air conditioner operates in fan

three

not start

minutes

 

mode.)

 

Air does not blow or the fan

When it is excessively cooled during dehumidifying, the blower

speed can not be changed during

automatically repeats reducing and lowering the fan speed.

 

dehumidifying

 

 

During operation, operation mode

Isn't the AUTO mode selected?

 

has changed over automatically.

In the case of AUTO mode, operation mode is changed automati-

 

cally from cooling to heating or vise-versa according to the room

 

temperature.

 

Water or steam generates from

This results when frost accumulated on the outdoor unit is removed

the outdoor unit during heating.

(during defrosting operation).

 

8

Image 9
Contents DUCT TYPE AIR CONDITIONER AD182AMBEAECO AD242AMBEAECO AD28NAMBEAECOAD36NAMBEAECO AD42NAMBEAECO Table of Contents Cautions Safety Instructions and WarningsDisposal of the old air conditioner Safety Precautions CAUTIONS FOR INSTALLATIONCAUTIONS FOR OPERATION CAUTIONS FOR TRANSFER OR REPAIR Safety PrecautionsThe machine is adaptive in following situation Safety PrecautionsParts and Functions AD182AMBEAECO AD242AMBEAECO AD28NAMBEAECOAD36NAMBEAECO AD42NAMBEAECO Unit fails to start MalfunctionCooling or heating is not sufficient Cooling is not sufficientThe followings are not malfunction MalfunctionCleaning Care and MaintenanceCare and Cleaning of the unit Points to observeWARMING OPERATION For Preparation of HeatingHot KeepWhen heating is started When the room thermostat is actuatedInstallation place Is The Unit Installed CorrectlyFor inspection and maintenance Electric work1. Safety precautions Installation Manual For Indoor UnitInstallation Manual For Indoor Unit b Hanger bolts installation Installation Manual For Indoor UnitAD36NAMBEAECO AD42NAMBEAECO5 Installation of indoor unit Installation Manual For Indoor UnitAdjusting to the levelness When the high performance filter is used7 Installation work for air outlet ducts Installation Manual For Indoor UnitABlowout duct 8 Connection of suction, exhaust ducts5. Electric wiring Installation Manual For Indoor Unit2.5mm2 HAIER GROUP