Haier AD36NAMBEA(ECO) Safety Precautions, The machine is adaptive in following situation

Page 6
The machine is adaptive in following situation

Manual background Safety Precautions

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

10

 

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

15

--

--

 

 

outdoor

DB C

7

24

-7

 

WB C

6

18

--

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable are self-provided. The power cable parameter is:

1)H07RN-F 5G 2.5mm2 (380-400V, 3N~, 50Hz),(AD42NAMBEA(ECO) AD36NAMBEA(ECO)AD28NAMBEA(ECO) ) ;

2)H05RN-F 3G 4.0mm2 (1PH,220-230V~,50Hz)(AD28NAMBEA(ECO) AD242AMBEA(ECO));

3)H05RN-F 3G 2.5mm2 (1PH,220-230V~,50Hz)(AD182AMBEA(ECO)).

The connecting cable should be H05RN-F 4x0.75mm2

All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.

6.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.

7.The indoor unit installation height is at least 2.5m.

8.The air breaker and the power switch should installed the converiently reachable place for user.

5

Image 6
Contents DUCT TYPE AIR CONDITIONER AD182AMBEAECO AD242AMBEAECO AD28NAMBEAECOAD36NAMBEAECO AD42NAMBEAECO Table of Contents Cautions Safety Instructions and WarningsDisposal of the old air conditioner Safety Precautions CAUTIONS FOR INSTALLATIONCAUTIONS FOR OPERATION Safety Precautions CAUTIONS FOR TRANSFER OR REPAIRSafety Precautions The machine is adaptive in following situationParts and Functions AD182AMBEAECO AD242AMBEAECO AD28NAMBEAECOAD36NAMBEAECO AD42NAMBEAECO Cooling or heating is not sufficient MalfunctionUnit fails to start Cooling is not sufficientMalfunction The followings are not malfunctionCare and Cleaning of the unit Care and MaintenanceCleaning Points to observeWhen heating is started For Preparation of HeatingHot KeepWARMING OPERATION When the room thermostat is actuatedFor inspection and maintenance Is The Unit Installed CorrectlyInstallation place Electric workInstallation Manual For Indoor Unit 1. Safety precautionsInstallation Manual For Indoor Unit AD36NAMBEAECO Installation Manual For Indoor Unitb Hanger bolts installation AD42NAMBEAECOAdjusting to the levelness Installation Manual For Indoor Unit5 Installation of indoor unit When the high performance filter is usedABlowout duct Installation Manual For Indoor Unit7 Installation work for air outlet ducts 8 Connection of suction, exhaust ducts5. Electric wiring Installation Manual For Indoor Unit2.5mm2 HAIER GROUP