PRECAUTION

2. Preparation for installation Instructions to installation

Manual backgroundWARNING

Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

Manual background CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire. For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

PRECAUTION

Manual background Execute proper grounding. Do not connect the earth wire to a gas pipe, water pipe, lightening rod, or a telephone ground wire. Improper placement of earth wires can result in electric shock.

Manual background An electric leakage breaker must be installed, otherwise electric shock or other accidents would occur.

Manual background After completion of the installation, the air conditioner shall be electrified to check for electric leakage.

2. Preparation for installation

Installation tools

1

2

3

4

5

6

7

Screw Driver (flat head, wabbler, triangle)

Steel Saw

60mm Drill

Inner Hexagon Spanner

Shifting Spanner

Spanner

Pipe Cutter

8

9

10

11

12

13

14

Pipe Expander

Knives

Clippers

Leakage Checker or Soap Liquid

Measuring Tape

Scraper or File

Refrigeration Oil

13