Installation for air duct of indoor unit

1. Installation of air discharge duct Instructions to installation

Manual background The distance between air duct outlet and air conditioner outlet is according to the length of actually installed air duct and in service behavior of the static pressure terminal: Installation sketch map for long and short air duct is showed below, when connect to short air duct, using low static terminal (terminal color is white), the distance between air duct outlet and air conditioner outlet is no more than 0.5m; when connect to long air duct, using middle static terminal (terminal color is red), the distance between air duct outlet and air conditioner outlet could be within 5m at this point.

Figure 5

sling dog

joint of air diffuser

 

drain piping

 

air return duct

 

transition air outlet

air diffuser

air return shutter air duct duct

 

Manual background Drain piping of condensed water should keep a downhill grade of 1% or more. Use insulating pipe to cover the drain piping of condensed water to keep warmth.

Manual background As figure shown, suspend and install the unit.

Figure 6

M8 broad foundation bolt

 

M8 suspension screw

Unit

 

M8 broad lock ring Manual backgroundManual background

M8 nut

Installation for air duct of indoor unit

1. Installation of air discharge duct

This type of unit uses circular air duct with its caliber of 180mm.

An additional transitive air duct is necessary for the circular air duct to connect to the air supply inlet. It should be also connected to its respective air diffuser separately. See Fig.1. Adjust the wind speed of each air diffuser outlet to keep in line on the whole, so as to meet a demand of the air conditioner in the room.

 

flexible joint or

transitive air duct

Indoor unit

static pressure

circular air duct

 

box

joint of air diffuser

air diffuser

Fig1: Duct connected

16

Page 18
Image 18