Haier AD092XLERA, AD182XLERA, AD142XLERA Failure code, Failrue codes maked with * are resumable

Models: AD092XLERA AD122XLERA AD142XLERA AD182XLERA

1 28
Download 28 pages 33.88 Kb
Page 27
Image 27
3.Failrue codes maked with * are resumable.

Manual background Failure code

TROUBLE SHOOTING

FAILURE CODE

POSSIBLE REASONS

(outdoor unit)

(CHECK THE WIRED

REMOTE CONTROLLER)

 

 

 

Faulty 4-way valve

25

 

Coil of 4-way valve is disconnected, or faulty

switching on

 

outdoor PCB

 

 

 

 

 

 

Faulty sensor Tc

26

*

Sensor disconnected, or broken, or short circuit

 

Faulty sensor Toci

2A

*

Sensor disconnected, or broken, or short circuit

 

Low voltage protection

2C

VDC<194V, too low voltage from power source

 

 

 

 

 

High voltage protection

2D

 

VDC>400V, too high voltage from power source

 

 

 

 

Abnormal communication

2E

 

Communication cables broken, or not be well

between main PCB and

 

connected, or faulty main PCB, or faulty SPDU

SPDU(or ISPM)

 

 

(or ISPM)

Compressor be locked

32

 

Faulty compressor or SPDU(or ISPM)

Compressor vibration too big

33

 

Faulty compressor

Compressor lose position

34

 

Faulty SPDU(or ISPM)

Faulty compressor start

35

 

Faulty compressor or SPDU(or ISPM)

 

 

 

 

Faulty position checking

37

 

Faulty SPDU(or ISPM)

circuit

 

 

 

 

 

 

 

 

Compressor broken

38

 

Faulty compressor or SPDU(or ISPM)

 

 

 

 

NOTE!

1.Please contact the installers or distributors when trouble happens to repair it.

2.Turn the power off and power on again, if the failure code recurs, please inform the franchiser.

3.Failrue codes maked with * are resumable.

25

Page 27
Image 27
Haier AD092XLERA, AD182XLERA, AD142XLERA, AD122XLERA Failure code, Failrue codes maked with * are resumable