3.5VENTING APPLICATION FLOW CHART

TOP EXIT

Horizontal Termination

 

 

Vertical Termination

 

 

 

 

 

 

 

 

 

 

 

Vertical rise is equal

to or greater than the horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Vertical rise is less than horizontal run

Horizontal run +

vertical rise to

maximum of 24.75

feet

4.2times the

vertical rise equal to or greater than the horizontal run

Vertical rise is equal

to or greater than the horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Vertical rise is less than horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

3 times the vertical

rise equal to or greater than the horizontal run

13.1

REAR EXIT

Horizontal Termination

Vertical Termination

Vertical rise is equal

to or greater than the horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Vertical rise is less than horizontal run

Horizontal run +

vertical rise to

maximum of 24.75

feet

3.5times the

vertical rise equal to or greater than the horizontal run

Vertical rise is equal

to or greater than the horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

Vertical rise is less than horizontal run

Horizontal run +

vertical rise to

maximum of 40 feet

3 times the vertical

rise equal to or greater than the horizontal run

13.2

W415-0788 / A / 09.22.09

Page 15
Image 15