Napoleon Fireplaces GDS60N manual Symptom Problem Test Solution

Models: GDS60N

1 52
Download 52 pages 27.89 Kb
Page 49
Image 49

49

SYMPTOM

PROBLEM

TEST SOLUTION

Carbon is being deposited on glass, logs, rocks, media or combustion chamber surfaces.

Air shutter has become

- Ensure air shutter opening is free of lint or other

blocked.

obstructions.

Flame is impinging on the

- Check that the glass, logs, rocks or media are

glass, logs, rocks, media

correctly positioned.

or combustion chamber.

- Open air shutter to increase the primary air.

 

- Check the input rate: check the manifold pressure

 

and orifice size as specified by the rating plate

 

values.

 

- Check that the door gasketing is not broken or

 

missing and that the seal is tight.

 

- Check that both vent liners are free of holes and

 

well sealed at all joints.

 

- Check that minimum rise per foot has been adhered

 

to for any horizontal venting.

Continues to spark and pilot lights, but main burner will not light.

Short or loose

- Verify all connections. Verify the connections

connection in sensor rod.

from the pilot assembly are tight; also verify these

 

connections are not grounding out to any metal.

Poor flame rectification

- Verify the flame is engulfing the sensor rod. This

or contaminated

will increase the flame rectification. Verify correct

sensor rod.

pilot orifice is installed and inlet gas specifications

 

to manual. (Remember, the flame carries the

 

rectification current, not the gas. If the flame lifts

 

from pilot hood, the circuit is broken. A wrong orifice

 

or too high of an inlet pressure can cause the pilot

 

flame to lift.) The sensor rod may need cleaning.

Poor grounding between

- Verify that the wire harness is firmly connected to

pilot assembly and

module Verify that the ceramic insulator around the

gas valve.

sensor rod is not cracked, damaged, or loose. Verify

 

the connection from the sensor rod to the sensor wire.

Damaged pilot or dirty

- Clean sensor rod with an emery cloth to remove

sensor rod.

any contamination that may have accumulated on

 

the sensor rod. Verify continuity with multimeter with

 

ohms set at the lowest range.

Pilot lights

Wiring / Connection.

- Inspect all wires, ensure good tight connections.

Stops sparking

 

 

Verify that all wiring is installed exactly as specified.

/ pilot remains lit

Wiring harness.

- Inspect the wiring harness, and verify the harness

but burner will

 

 

is tightly connected to the module. Verify that all

not turn on.

 

 

wires are connected in the right order. See “WIRING

 

 

 

DIAGRAM” section.

Exhaust fumes

Appliance is spilling.

- Check all seals.

smelled in room,

 

 

- Check if exhaust is re-entering through an open

headaches.

 

 

door or window.

 

 

 

 

42.7_2

 

 

 

 

W415-0788 / A / 09.22.09

Page 49
Image 49
Napoleon Fireplaces GDS60N manual Symptom Problem Test Solution