5.7.2 INSTALLING "B" VENT

31

5.7.2 INSTALLING "B" VENT

Follow the instructions of the "B" vent manufacturer for chim- ney installation.

A.Remove the access plate. Remove and discard the air intake cover plate located directly behind the ac- cess plate.

B.Feed the 2 wires, supplied, through the 7" collar at the top of the unit, bring them out the air intake opening but behind the rear panel as shown.

NOTE: Ensure that 2 female ends remain at the top. Re-secure the access plate.

ACCESS PLATE LOCATION ADAPTER

C.

Remove the spill switch bracket from the rear of the

FIGURE 5.7.2a

 

adapter. Unscrew the spill switch and discard the

 

 

bracket. Attach the spill switch to the bracket supplied

 

 

with the appliance and secure onto the adapter.

AIR INTAKE COVER

 

 

D.

Bring the wires through the lower hole in the adapter.

PLATE LOCATION

 

 

To pass the wires through the hole more easily, tem-

 

 

porarily tape the two terminals together.

FIGURE 5.7.2g

 

 

E.

With the spill switch opening aligned to the back of the ap-

ADAPTER

 

pliance, take hold of the adapter base and push the crimped

 

edge into the appliance flue collar.

SPILL

 

 

F.

Connect the upper wire terminals to the spill switch.

SWITCH

G.

Disconnect the wire leads to on/off switch, see "WIRING

 

 

DIAGRAM" section and reconnect to the ends of the spill

 

 

switch wires. Leave all excess wire in an orderly manner.

 

For aesthetics, the adapter has been designed to accept a standard matte black 7" appliance pipe and the Napoleon® decorative brass band (standard with the GS-150KT). Both are available from your local authorized dealer / distributor.

5.7.3 B-VENT

Attach the B-Vent label, shown, in the control area of the appliance.

ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.

THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.

ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.

CEFOYERAETECONVERTIAUNMODELEASYSTEMED’EVACUATION‘B’.

WS-385-160

5.7.4 COMBUSTION AIR

This appliance needs air for safe operation and must be installed in such a way that adequate combustion air is available.

W415-0788 / A / 09.22.09