3.11 TOP OR REAR EXIT VERTICAL TERMINATION

21

3.11 TOP OR REAR EXIT VERTICAL TERMINATION

(HT) < (VT)

Simple venting configurations.

See graph to determine the required vertical rise VT for the

 

required horizontal run HT.

REQUIRED

VERTICAL

RISE IN

FEET VT

FIGURE 3.11a

40

 

 

 

 

30

 

 

 

 

20

 

 

 

 

10

 

 

 

 

3

 

 

 

 

0

5

10

15

20

 

 

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT

 

 

 

 

The shaded area within the lines represents acceptable

 

 

 

 

 

values for HT and HT

 

For vent configurations requiring one or more 90° elbows (top exit) or one or more 90° elbows (rear exit),

the following formulas apply:

 

 

 

Formula 1: HT

< VT

 

 

 

Formula 2: HT

+ VT < 40 feet

 

 

 

Example 6:

 

 

90°

 

V1

= 5 FT

 

 

V3

 

 

 

V2

= 6 FT

 

 

 

 

 

90°

 

V3

= 10 FT

 

 

 

VT

= V1

+ V2 + V3 = 5 + 6 + 10 = 21 FT

 

H

2

H1

= 8 FT

 

 

V2

H2

= 2.5 FT

 

FIGURE 3.11b

H1

90°

HR

= H1

+ H2 = 8 + 2.5 = 10.5 FT

V1

 

 

 

HO

= .03 (four 90° elbows - 90°)

 

90°

 

= .03 (360° - 90°) = 8.1 FT

 

HT

= HR

+ HO = 10.5 + 8.1 = 18.6 FT

 

 

 

HT

+ VT

= 18.6 + 21 = 39.6 FT

 

 

 

Formula 1:

HT

< 3.5 VT

 

18.6 < 21

Formula 2:

HT

+ VT < 40 FT

 

39.6 < 40

Since both formulas are met, this vent configuration is acceptable.