Napoleon Fireplaces GDS60N manual 3.6DEFINITIONS, 3.7ELBOW VENT LENGTH VALUES, Feet, Inches

Models: GDS60N

1 52
Download 52 pages 27.89 Kb
Page 16
Image 16
3.6DEFINITIONS

16

3.6DEFINITIONS

For the following symbols used in the venting calculations and examples are:

>- greater than

>- equal to or greater than < - less than

< - equal to or less than

HT - total of both horizontal vent lengths (Hr) and offsets (Ho) in feet HR - combined horizontal vent lengths in feet

HO - offset factor: .03 (total degrees of offset - 90°*) in feet VT - combined vertical vent lengths in feet

14.1

3.7ELBOW VENT LENGTH VALUES

 

FEET

INCHES

0.03

0.5

15°

0.45

6.0

30°

0.9

11.0

45°

1.35

16.0

90°*

2.7

32.0

* The first 90° offset has a zero value and is shown in the formula as - 90°

15.1

W415-0788 / A / 09.22.09