5.2WALL AND CEILING PROTECTION

26

5.2WALL AND CEILING PROTECTION

!WARNING

DO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OF MATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS. ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS. INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OR OTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.

70.1

For optimum performance, it is recommended that all horizontal runs have a minimum 1/4" rise per foot when venting. For safe and proper operation of the appliance, follow the venting instructions exactly.

5.2.1 HORIZONTAL INSTALLATION

!WARNING

THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.

TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE

RETURN FLANGE OF THE MOUNTING PLATE.

This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal

location, cut and frame a hole in the exterior wall as

 

illustrated to accommodate the firestop assembly.

CAULKING

Dry fit the firestop assembly before proceeding to

 

ensure the brackets on the rear surface fit to the

 

inside surface of the horizontal framing.

FIRESTOP

 

The length of the vent shield may be cut shorter

SPACER

for combustible walls that are less than 8 1/2” thick

 

but the vent shield must extend the full depth of the

 

combustible wall.

 

VENT

SHIELD

10"1/2 5.2.1 HORIZONTAL INSTALLATION10"1/2  9 1/2" 9 1/2"Manual background

DETERMINE THE CORRECT HEIGHT

A. Apply a bead of caulking (not supplied) around the corner edge of

FINISHING

the inside surface of the firestop assembly, fit the firestop

MATERIAL

assembly to the hole and secure using the 4 screws W570-0026

 

(supplied in your manual baggie).

FIGURE 5.2.1

 

B.Once the vent pipe is installed in its final position, apply high temperature sealant W573-0007 (not supplied) between the pipe and the firestop.

20.2

W415-0788 / A / 09.22.09

Page 26