7.0 OPTIONAL BLOWER INSTALLATION

38

7.0 OPTIONAL BLOWER INSTALLATION

7.0.1 Ensure that the access cover plate has been

FIGURE 7.0.4 / 7.0.6

installed. For location, see "SWITCH AND

BRACKET INSTALLATION" section.

 

7.0.2Remove the on/off switch bracket and the cover plate below it. The switch spacers and cover plate may now be discarded.

7.0.3Decide which side of the blower housing you prefer the on/off switch to be located on.

7.0.4Remove the top 2 screws from the left outer edge of the rear appliance panel.

7.0.5Mount and secure the blower housing using 4 screws (two of which were removed in previous step). Ensure that the on/off switch wires pass through the appropriate slot located on either side of the blower housing.

SLOT

REMOVED SCREWS

7.0.6Remove the 2 screws from the side of the

blower housing that you want the switch to be located on and re-secure the on/off switch.

Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 minutes after lighting the appliance and will run for approximately 30-45 minutes after the appliance has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into blower bearings causing irreparable damage and must be prevented from coming into contact with the blower or its compartment.

Any damage resulting from this condition is not covered by the warranty policy.

FIGURE 7.0.5

FIGURE 7.0.6

W415-0788 / A / 09.22.09