Haier Comprehensive Heat Pump Manual for Optimal Heating

Page 19

FOR PREPARATION OF HEATING("HOT KEEP")

"HOT KEEP"is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost. the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour, and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating operation.

When the room thermostat is actuated:

When room temperature increases and room temperature controller actu- ates, the fan speed is automatically changed to stop under low temperature condition of indoor heat exchanger. When room temperature decreases, air conditioner automatically changes over to ordinary heating operation.

WARMING OPERATION

Heat pump type warming

With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized.

Defrosting operation

When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat ex- changer of outdoor unit along with the drop of indoor temperature. Since the accumulated frost re- duces the effect of warming, it is necessery to automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.

Atmospheric temperature and warming capacity

Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature.

When the warming capacity is not sufficient, it is recommended to use another

heating implement.

Period of warm-upSince the heat pump type air conditioner employs a method to circulate warm winds to warm the entire space of a room, it takes time before the room tem- perature rises.

It is recommendable to start the operation a little earlier in a very cold morning.

18

Image 19
Contents Manual Please read this manual carefully before usingTable of Contents Disposal of the old air conditioner It could cause such problems as water leakage Safety PrecationsMake sure to use a fuse of proper electric rating Safety PrecautionsApplicable ambient temperature range Safety PrecautionMachine is adaptive in following situation HDU-24H03/HHDU-42H03/H HDU-28H03/H Parts and FunctionsAir outlet Duct Drainpipe Air inlet Buttons and display of the wire controller Clock set Remote controlOperation Recommendations Select temp. settingFan speed selection Select your desired Timer mode on or OFF Set Clock correctly before starting Timer operationPress Time Select Offon Follow the same procedures in Time setting for Timer onPress Time button Heating mode Cooling, dehumidifying modeComfortable Sleep Operation Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientOutdoor unit during heating During defrosting operation Followings are not malfunctionStopped. Because the protecting circuit is activated During this time air conditioner operates in fanPoints to observe Care and MaintenanceWarming Operation Installation place Is the Unit Installed CorrectlyElectric work Installation Manual for Wire Controller Replace the upper part of wire controller Indoor unit wiringHint Installation AccessoriesSelection of the place of installation Installation of outdoor unitOutline piping Refrigerant pipingPiping size To use vacuum pump Model0mm 30mA Electric wiringWire size Switch Leak Rated capacity a Minimum 5mm 30mATest run Safety precautions Installation Manual for Indoor UnitChoose installation place Preparation before installation Drain Piping Installation of indoor unitInstallation of air suction and discharging duct Shape Square duct Dimension Air volume Chosen chart of simple ductAir discharging fan Improper example Examples of improper installationExample of the method of choosing capacity number Operation method of fan controllerRefrigerant pipe

HDU-28H03/H, HDU-42H03/H, HDU-24H03/H specifications

Haier has established itself as a leading name in the HVAC sector, and their HDU series, including models HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H, exemplifies the brand's commitment to quality and efficiency. These air conditioning units are ideal for both residential and commercial use, designed to provide optimal comfort without compromising on energy efficiency.

One of the standout features of the HDU series is its advanced inverter technology. This allows the units to adjust their cooling and heating output based on the current demand, ensuring that energy is used efficiently. As a result, users can expect reduced energy bills while enjoying a consistently comfortable indoor climate. The inverter system minimizes temperature fluctuations by maintaining a steady output, enhancing overall comfort.

Another notable aspect of the HDU models is their high energy efficiency ratings, often reaching levels that exceed industry standards. This is largely due to the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. The incorporation of R32 not only makes these units more environmentally friendly but also helps to improve efficiency, providing effective cooling and heating performance even in extreme weather conditions.

Additionally, the HDU units boast a wide operating temperature range. They are designed to work seamlessly in a variety of climates, maintaining performance in temperatures as low as -15°C for heating and up to 50°C for cooling. This adaptability makes them a versatile choice for different geographic locations.

Quiet operation is another impressive feature of the HDU series. The indoor units are engineered to operate at whisper-quiet levels, making them ideal for bedrooms, offices, or any space where noise could be a concern. This allows users to enjoy a peaceful environment while maintaining their comfort.

The user-friendly interface and smart features of the HDU models further enhance their appeal. Equipped with modern remote controls and optional Wi-Fi connectivity, users can easily manage their air conditioning settings from anywhere, providing convenience and flexibility.

In summary, the Haier HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H models combine advanced inverter technology, high energy efficiency, a wide operating temperature range, and quiet operation to deliver outstanding performance. Their smart features and eco-friendly refrigerant make them a reliable choice for those seeking comfort and efficiency in their HVAC systems.