Haier HDU-28H03/H Heat Pump model/Cooling Only model, Accessories, Installation of outdoor unit

Page 23

INSTALLATION MANUAL FOR OUTDOOR UNIT

<Heat Pump model/Cooling Only model >

WARNING

BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.

BE SURE TO READ INSTALLATION MANUAL FOR INDOOR UNIT WITH THIS MANUAL.

1. Accessories

Edging

"Edging" for protection of electric wires from an opening edge.

2. Selection of the place of installation

Select the place of installation satisfying the following conditions and, at the same time, obtain a consent from the client or user.

Place where air circulates.

Place free from heat radiation from other heat sources.

Place where drain water may be discharged.

Place where noise and hot air may not disturb the neighborhood.

Place where there is not heavy snowfall in the winter time.

Place where obstacles do not exist near the air inlet and air outlet .

Place where the air outlet may not be exposed to a strong wind.

Place surrounded at four sides are not suitable for installation. A 1m or more of overhead space is needed for the unit.

Mount guide-louvers to place where short-circuit is a possibility.

When installing several units, secure sufficient suction space to avoid short circuiting.

(1) Open space requirement around the unit

Air inlet L3

L2

Air inlet

Air outlet

L1

500

(Servicing

space)

 

 

 

 

 

 

 

Unit: mm

Distance

Case

 

I

 

II

 

III

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

open

 

open

 

500

 

 

 

 

 

 

 

 

L2

 

 

300

 

0

 

open

 

 

 

 

 

 

 

 

L3

 

 

150

 

300

 

150

 

 

 

 

 

 

 

 

(2) Installation where the area with strong winds.

Install the unit so that the air outlet section of the unit must NOT be faced toward wind direction.

3.Installation of outdoor unit

(1)Installation

NO

Wind direction

Fix the unit in a proper way according to the condition of a place where it is installed by referring to the following .

(a)Concrete foundation

Unit

Anchor bolt

 

 

 

 

 

 

 

Concrete foundation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To fix by bolts

Note (1) Give enough room for the concrete foundation to fix by anchor bolts.

Foundation anchor

Unit

Concrete foundation

Anchor bolt

Note (1) Place the concrete foundation deep enough.

Install the unit so that the angle of inclination must be less than 3 degrees.

22

Image 23
Contents Manual Please read this manual carefully before usingTable of Contents Disposal of the old air conditioner It could cause such problems as water leakage Safety PrecationsMake sure to use a fuse of proper electric rating Safety PrecautionsMachine is adaptive in following situation Safety PrecautionApplicable ambient temperature range Air outlet Duct Drainpipe Air inlet Parts and FunctionsHDU-24H03/HHDU-42H03/H HDU-28H03/H Buttons and display of the wire controller Clock set Remote controlOperation Fan speed selection Select temp. settingRecommendations Press Time Set Clock correctly before starting Timer operationSelect your desired Timer mode on or OFF Press Time button Follow the same procedures in Time setting for Timer onSelect Offon Comfortable Sleep Cooling, dehumidifying modeHeating mode Operation Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientOutdoor unit during heating During defrosting operation Followings are not malfunctionStopped. Because the protecting circuit is activated During this time air conditioner operates in fanPoints to observe Care and MaintenanceWarming Operation Electric work Is the Unit Installed CorrectlyInstallation place Installation Manual for Wire Controller Hint Indoor unit wiringReplace the upper part of wire controller Installation AccessoriesSelection of the place of installation Installation of outdoor unitPiping size Refrigerant pipingOutline piping To use vacuum pump Model0mm 30mA Electric wiringWire size Switch Leak Rated capacity a Minimum 5mm 30mATest run Safety precautions Installation Manual for Indoor UnitChoose installation place Preparation before installation Drain Piping Installation of indoor unitInstallation of air suction and discharging duct Shape Square duct Dimension Air volume Chosen chart of simple ductAir discharging fan Improper example Examples of improper installationExample of the method of choosing capacity number Operation method of fan controllerRefrigerant pipe

HDU-28H03/H, HDU-42H03/H, HDU-24H03/H specifications

Haier has established itself as a leading name in the HVAC sector, and their HDU series, including models HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H, exemplifies the brand's commitment to quality and efficiency. These air conditioning units are ideal for both residential and commercial use, designed to provide optimal comfort without compromising on energy efficiency.

One of the standout features of the HDU series is its advanced inverter technology. This allows the units to adjust their cooling and heating output based on the current demand, ensuring that energy is used efficiently. As a result, users can expect reduced energy bills while enjoying a consistently comfortable indoor climate. The inverter system minimizes temperature fluctuations by maintaining a steady output, enhancing overall comfort.

Another notable aspect of the HDU models is their high energy efficiency ratings, often reaching levels that exceed industry standards. This is largely due to the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. The incorporation of R32 not only makes these units more environmentally friendly but also helps to improve efficiency, providing effective cooling and heating performance even in extreme weather conditions.

Additionally, the HDU units boast a wide operating temperature range. They are designed to work seamlessly in a variety of climates, maintaining performance in temperatures as low as -15°C for heating and up to 50°C for cooling. This adaptability makes them a versatile choice for different geographic locations.

Quiet operation is another impressive feature of the HDU series. The indoor units are engineered to operate at whisper-quiet levels, making them ideal for bedrooms, offices, or any space where noise could be a concern. This allows users to enjoy a peaceful environment while maintaining their comfort.

The user-friendly interface and smart features of the HDU models further enhance their appeal. Equipped with modern remote controls and optional Wi-Fi connectivity, users can easily manage their air conditioning settings from anywhere, providing convenience and flexibility.

In summary, the Haier HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H models combine advanced inverter technology, high energy efficiency, a wide operating temperature range, and quiet operation to deliver outstanding performance. Their smart features and eco-friendly refrigerant make them a reliable choice for those seeking comfort and efficiency in their HVAC systems.