Haier HDU-42H03/H, HDU-24H03/H Installation Manual for Indoor Unit, Safety precautions

Page 28

INSTALLATION MANUAL FOR INDOOR UNIT

Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

 

 

 

Though the precautionary points indicated herein are divided under two headings,

 

WARNING

 

and

 

, those points which are related to the strong possibility of an

installation done in error

CAUTION

resulting in death or

serious injury are listed in the

WARNING

section. However, there is also a

possibility of serious consequences in relationship to the points listed in

the

 

section as well.

CAUTION

In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R22) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

26

Image 28
Contents Please read this manual carefully before using ManualTable of Contents Disposal of the old air conditioner Safety Precations It could cause such problems as water leakageSafety Precautions Make sure to use a fuse of proper electric ratingApplicable ambient temperature range Safety PrecautionMachine is adaptive in following situation HDU-24H03/HHDU-42H03/H HDU-28H03/H Parts and FunctionsAir outlet Duct Drainpipe Air inlet Buttons and display of the wire controller Remote control Clock setOperation Recommendations Select temp. settingFan speed selection Select your desired Timer mode on or OFF Set Clock correctly before starting Timer operationPress Time Select Offon Follow the same procedures in Time setting for Timer onPress Time button Heating mode Cooling, dehumidifying modeComfortable Sleep Operation Malfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientFollowings are not malfunction Stopped. Because the protecting circuit is activatedDuring this time air conditioner operates in fan Outdoor unit during heating During defrosting operationCare and Maintenance Points to observeWarming Operation Installation place Is the Unit Installed CorrectlyElectric work Installation Manual for Wire Controller Replace the upper part of wire controller Indoor unit wiringHint Accessories Selection of the place of installationInstallation of outdoor unit InstallationOutline piping Refrigerant pipingPiping size Model To use vacuum pumpElectric wiring Wire size Switch Leak Rated capacity a Minimum5mm 30mA 0mm 30mATest run Installation Manual for Indoor Unit Safety precautionsChoose installation place Preparation before installation Installation of indoor unit Drain PipingInstallation of air suction and discharging duct Chosen chart of simple duct Shape Square duct Dimension Air volumeExamples of improper installation Air discharging fan Improper exampleOperation method of fan controller Example of the method of choosing capacity numberRefrigerant pipe

HDU-28H03/H, HDU-42H03/H, HDU-24H03/H specifications

Haier has established itself as a leading name in the HVAC sector, and their HDU series, including models HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H, exemplifies the brand's commitment to quality and efficiency. These air conditioning units are ideal for both residential and commercial use, designed to provide optimal comfort without compromising on energy efficiency.

One of the standout features of the HDU series is its advanced inverter technology. This allows the units to adjust their cooling and heating output based on the current demand, ensuring that energy is used efficiently. As a result, users can expect reduced energy bills while enjoying a consistently comfortable indoor climate. The inverter system minimizes temperature fluctuations by maintaining a steady output, enhancing overall comfort.

Another notable aspect of the HDU models is their high energy efficiency ratings, often reaching levels that exceed industry standards. This is largely due to the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. The incorporation of R32 not only makes these units more environmentally friendly but also helps to improve efficiency, providing effective cooling and heating performance even in extreme weather conditions.

Additionally, the HDU units boast a wide operating temperature range. They are designed to work seamlessly in a variety of climates, maintaining performance in temperatures as low as -15°C for heating and up to 50°C for cooling. This adaptability makes them a versatile choice for different geographic locations.

Quiet operation is another impressive feature of the HDU series. The indoor units are engineered to operate at whisper-quiet levels, making them ideal for bedrooms, offices, or any space where noise could be a concern. This allows users to enjoy a peaceful environment while maintaining their comfort.

The user-friendly interface and smart features of the HDU models further enhance their appeal. Equipped with modern remote controls and optional Wi-Fi connectivity, users can easily manage their air conditioning settings from anywhere, providing convenience and flexibility.

In summary, the Haier HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H models combine advanced inverter technology, high energy efficiency, a wide operating temperature range, and quiet operation to deliver outstanding performance. Their smart features and eco-friendly refrigerant make them a reliable choice for those seeking comfort and efficiency in their HVAC systems.