Haier HDU-28H03/H, HDU-24H03/H, HDU-42H03/H instruction manual Choose installation place

Page 29

INSTALLATION MANUAL FOR INDOOR UNIT

NOTICE

All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to your local distributor.

WARNING

BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAI- LURE TO FOLLOW THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR PROPERTY DAMAGE.

1.Before installation [Before finishing installation, do not throw the attached parts installation needs]

Confirm the way to move the unit to the installation place.

Before moving the unit to the installation place, do not remove their packages.

When have to remove the package, use a soft material or protection board with rope to lift the unit assembly to avoid unit damage or bumping a scrape.

2. Choose installation place

(1) The chosen installation place should meet the following requirements and get the userís consent.

Place ensures ideal airflow distribution.

The passage of airflow has no obstacles.

When importing outside air, it should be imported directly from outdoors. (if the pipe can not be extended, it also can not be imported from top)

Place ensures enough space for maintenance.

The pipe length between indoor and outdoor unit is in the permitted limit (referring to outdoor unit installation part).

The indoor unit, outdoor unit, electric wire and connection wire is at least 1m away from television and radio. This is to avoid the image disturbance and noise caused by the above-mentioned home appliance. (Even if 1m away, if the electromagnetic wave is too strong, it can also cause noise.)

(2) The height of ceiling

The indoor unit can install on the ceiling, which height is no more than 3m.

(3)Install and use the hoisting screw. Check if the installation place can bear the weight of unit assembly.

If not certain, strengthen it before install the unit.

Over 100

Over 900

Air out

Checking meatus

(600x600)

 

Air in

Over 200 Over 300

Ceiling

28

Image 29
Contents Manual Please read this manual carefully before usingTable of Contents Disposal of the old air conditioner It could cause such problems as water leakage Safety PrecationsMake sure to use a fuse of proper electric rating Safety PrecautionsMachine is adaptive in following situation Safety PrecautionApplicable ambient temperature range Air outlet Duct Drainpipe Air inlet Parts and FunctionsHDU-24H03/HHDU-42H03/H HDU-28H03/H Buttons and display of the wire controller Clock set Remote controlOperation Fan speed selection Select temp. settingRecommendations Press Time Set Clock correctly before starting Timer operationSelect your desired Timer mode on or OFF Press Time button Follow the same procedures in Time setting for Timer onSelect Offon Comfortable Sleep Cooling, dehumidifying modeHeating mode Operation Unit fails to start MalfunctionCooling or heating is not sufficient Cooling is not sufficientStopped. Because the protecting circuit is activated Followings are not malfunctionDuring this time air conditioner operates in fan Outdoor unit during heating During defrosting operationPoints to observe Care and MaintenanceWarming Operation Electric work Is the Unit Installed CorrectlyInstallation place Installation Manual for Wire Controller Hint Indoor unit wiringReplace the upper part of wire controller Selection of the place of installation AccessoriesInstallation of outdoor unit InstallationPiping size Refrigerant pipingOutline piping To use vacuum pump ModelWire size Switch Leak Rated capacity a Minimum Electric wiring5mm 30mA 0mm 30mATest run Safety precautions Installation Manual for Indoor UnitChoose installation place Preparation before installation Drain Piping Installation of indoor unitInstallation of air suction and discharging duct Shape Square duct Dimension Air volume Chosen chart of simple ductAir discharging fan Improper example Examples of improper installationExample of the method of choosing capacity number Operation method of fan controllerRefrigerant pipe

HDU-28H03/H, HDU-42H03/H, HDU-24H03/H specifications

Haier has established itself as a leading name in the HVAC sector, and their HDU series, including models HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H, exemplifies the brand's commitment to quality and efficiency. These air conditioning units are ideal for both residential and commercial use, designed to provide optimal comfort without compromising on energy efficiency.

One of the standout features of the HDU series is its advanced inverter technology. This allows the units to adjust their cooling and heating output based on the current demand, ensuring that energy is used efficiently. As a result, users can expect reduced energy bills while enjoying a consistently comfortable indoor climate. The inverter system minimizes temperature fluctuations by maintaining a steady output, enhancing overall comfort.

Another notable aspect of the HDU models is their high energy efficiency ratings, often reaching levels that exceed industry standards. This is largely due to the use of R32 refrigerant, which has a lower global warming potential compared to traditional refrigerants. The incorporation of R32 not only makes these units more environmentally friendly but also helps to improve efficiency, providing effective cooling and heating performance even in extreme weather conditions.

Additionally, the HDU units boast a wide operating temperature range. They are designed to work seamlessly in a variety of climates, maintaining performance in temperatures as low as -15°C for heating and up to 50°C for cooling. This adaptability makes them a versatile choice for different geographic locations.

Quiet operation is another impressive feature of the HDU series. The indoor units are engineered to operate at whisper-quiet levels, making them ideal for bedrooms, offices, or any space where noise could be a concern. This allows users to enjoy a peaceful environment while maintaining their comfort.

The user-friendly interface and smart features of the HDU models further enhance their appeal. Equipped with modern remote controls and optional Wi-Fi connectivity, users can easily manage their air conditioning settings from anywhere, providing convenience and flexibility.

In summary, the Haier HDU-28H03/H, HDU-42H03/H, and HDU-24H03/H models combine advanced inverter technology, high energy efficiency, a wide operating temperature range, and quiet operation to deliver outstanding performance. Their smart features and eco-friendly refrigerant make them a reliable choice for those seeking comfort and efficiency in their HVAC systems.