Monessen Hearth WDV500 venting installation, How To Use The Vent Graph, WDV Series Gas Fireplace

Models: WDV500

1 48
Download 48 pages 40 Kb
Page 13
Image 13
venting installation

venting installation

WDV Series Gas Fireplace

 

 

termination clearances for buildings with combustible and noncombustible exteriors

How To Use The Vent Graph Gthe outer wall must not exceed 16' (4.9 m). G=6" (152mm)

Manual backgroundManual background V Manual backgroundManual background

Combustible – 6" (152 mm)

Noncombustible – 2" (51 mm)

Inside Corner

G

V Manual backgroundManual backgroundManual background

G = Combustible 24"(610mm) Noncombustible 18"(457mm)

V

Manual background F Manual background F=6" (152mm)

Outside Corner

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

 

D

C

C

 

V

Manual background E Manual background

C = Maximum depth of 48" (1219mm) for alcove location

D = Minimum width for back wall of alcove location Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in alcove location

Combustible - 6" (152mm)

Noncombustible - 2" (51mm)

 

Balcony with No Side Wall

Balcony with Perpendicular

 

 

 

Alcove Location

 

Figure 9 -

Side Wall

40

 

 

 

 

Allowable Venting Chart

 

 

 

 

 

 

 

 

 

 

38

 

 

 

 

 

 

 

Feet

36

 

 

CenteroftheHorizontalVentPipe

VerticalDimensionFromtheFloorofUnit

How To Use The Vent Graph

 

34

 

 

The Vent Graph should be read in conjunction with the

in

32

 

 

 

 

Dimensions

30

 

 

 

 

following vent installation instructions to determine the

 

 

 

 

 

 

 

 

 

relationship between the vertical and horizontal dimensions

 

28

 

 

 

 

of the vent system.

 

 

26

 

 

 

 

1. Determine the height of the center of the horizontal vent

 

24

 

 

 

 

 

pipe exiting through the outer wall. Using this dimen-

 

22

 

 

 

 

 

sion on the Sidewall Vent Graph below, locate the point

 

20

 

 

 

 

 

intersecting with the slanted graph line.

 

50"

18

 

 

eg: A

 

2.

From the point of this intersection, draw a vertical line

16

 

 

 

From Floor to

 

 

 

 

to the bottom of the graph.

 

Center

14

 

 

 

 

3.

Select the indicated dimension, and position the fire-

 

12

 

 

 

 

 

place in accordance with same.

 

 

10

 

 

 

to

 

Example: If the vertical dimension from the floor of the

 

8

 

 

 

 

 

 

 

 

the

 

fireplace is 11' (3.4 m) the horizontal run to the face of

 

6

 

 

 

 

 

 

 

 

 

 

the outer wall must not exceed 16' (4.9 m).

 

4

 

 

 

 

Sidewall Vent Graph showing the relationship between

 

2

 

 

 

 

vertical and horizontal dimensions for a Direct Vent flue

 

2

4

6

8 10 1214 16 1820

 

system.

 

 

 

 

Horizontal dimension from the finished outside

 

 

 

 

 

Figure 10 -

wall to the center of the pipe on the fireplace

 

 

Rear Wall Venting Graph

 

 

 

 

78D0011

13

Page 13
Image 13
Monessen Hearth WDV500 manual venting installation, How To Use The Vent Graph, WDV Series Gas Fireplace, 78D0011