Monessen Hearth WDV500 manual WDV Series Gas Fireplace, Remote Control Operation, 78D0011

Models: WDV500

1 48
Download 48 pages 40 Kb
Page 34
Image 34
REMOTE CONTROL OPERATION

WDV Series Gas Fireplace

REMOTE CONTROL OPERATION

 

 

Flame Height Setting for Thermostatic Mode

Figure 43

1.Hold AUTO button for five (5) seconds and one number and flame icon will appear in LCD screen.

2.Use the ON / or OFF / button to set the desired flame height to 1 (min.) 2 (medium) or 3 (max.).

3. If there is no input within three (3) seconds, the new setting will be transmitted to the receiver. This setting only affects auto mode operation.

4. The default setting for transmitter is 2 (medium).

FP2147

Figure 43 -

Flame Height Setting Display

3-Speed Blower Control (Optional)

Figure 44

NOTE: Blower works automatically with flame.

1.Press FAN button once to enter blower speed setup mode at low speed initially and one of the three blade icons will display darken on LCD display. Figure 53

2.Continue to press FAN button to set up the blower speed you desire.

3.If there is no input within three (3) seconds, the new setting will be transmitted to receiver. If the fireplace is on, the blower speed will take effect right away; if the fire- place is off, the receiver will remember this setting and blower is still off.

4.If you continue to press FAN button to the position that all blades are gone, the FAN icon will disappear and turn the blower off.

Blower On Delay Time and OFF Delay Time Setting (Default 5 ON / 8 OFF)

Figure 45

1.Hold FAN button for three (3) seconds and two (2) numbers will appear in the LCD screen. The upper one is ON Delay Time and the bottom is OFF Delay Time in min- utes.

2.Use the ON / button to set the desired On Delay Time from 0 to 15 minutes.

3.Use the OFF / button to set the desired Off Delay Time from 0 to 15 minutes.

Flame Height Setting for Thermostatic Mode3-Speed Blower Control (Optional) °F

FP2145

Figure 44 -

3 Speed Blower Control

FP2146

Figure 45 -

Blower Delay Timer Display

3-Level Light Brightness Control

Figure 46

1.Press LIGHT button once to change light brightness to low and one of the three levels will display dark on LCD.

2.Continue to press LIGHT button to set up the light brightness you desire.

3.If there is no input within three (3) seconds, the new setting will be transmitted to the receiver.

4.If you continue to press LIGHT button, the LIGHT icon will disappear and turn the light off.

3-Level Light Brightness ControlManual background °F

FP2148

Figure 46 -

Light Brightness Display

34

78D0011

Page 34
Image 34
Monessen Hearth WDV500 WDV Series Gas Fireplace, Remote Control Operation, Flame Height Setting for Thermostatic Mode