Monessen Hearth WDV500 manual Command Center Functions/Operation, Command Center Operations, Fault

Models: WDV500

1 48
Download 48 pages 40 Kb
Page 32
Image 32
COMMAND CENTER FUNCTIONS/OPERATION

WDV Series Gas Fireplace

SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

COMMAND CENTER FUNCTIONS/OPERATION

Turning on the fireplace

1.Turn on the master switch and wait for a beep.

2.Press the ON button on the Command Center. Pilot will light and burner will come on High setting.

Pilot Safety Lockout Function

1.If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center flashes Green once every 2 seconds, until reset.

2.If the pilot flame is lost during normal operation, flame loss lockout happens. The LED on the Command Center flashes Red-Green once every 2 seconds, until reset.

3.Turning the master switch OFF, then ON again will reset the system.

Flame Height Control

1.Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.

2.Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and low.

3.The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent pilot configuration, the pilot will be shut off.

Turning the Fireplace Off

There are three ways to turn the fireplace off. (This will turn the entire system OFF.)

1.Flip the master switch to the off (“O”) position

2.Press the OFF button to Medium, Low, then Off.

3.Hold the OFF button anytime for three seconds. This command of OFF will remember all last settings before turning off. The next time the fireplace is turned on, all settings will resume. (Memory OFF)

Command Center Operations:

The following functions are available on the Command Center.

Function

Operation

Power Up

Flip the master switch to the ON ("_") position to power up the system

Fireplace ON

Press the ON button on the Command Center to turn the fireplace on

Fireplace OFF

Flip the master switch to the OFF ("o") position OR press the OFF button 3

 

times OR hold the OFF button 3 seconds (Memory OFF)

Flame Height Up

Press the ON button once to turn on the fireplace with maximum flame height

Flame Height Down

Press the OFF button to lower the flame height to Medium and Low

 

 

Self Diagnostics Chart:

The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a service call. Please refer to the charts below for indicator reference.

Fault

leD Indication

Conversion Cover Missing

One RED (1 time)

Spark Fail

Two RED (1 time)

No Sensor Signal

Three RED (1 time)

Pilot Lockout - trial

One GREEN, every 2 sec. (until manual reset)

Pilot Lockout - flame loss

One RED-GREEN, every 2 sec. (until manual reset)

Low Battery

One RED, every 10s (continuously)

No or Low Thermopile Power

Two RED, every 10s (continuously)

Learning

GREEN Flashes, every 1 sec. (for 10 sec.)

AC Power On

GREEN solid

 

 

32

78D0011

Page 32
Image 32
Monessen Hearth WDV500 manual Command Center Functions/Operation, Command Center Operations, Self Diagnostics Chart, Fault