Venting INSTALLATION INFORMATION

WDV Series Gas Fireplace

Venting INSTALLATION INFORMATION

 

 

WARNING

Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.

installation precautions

Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. The approved 5 x 8 venting components are Simpson Duravent and Selkirk products listed on Page 41. UL1777 flexible venting is also approved for use on these models. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.

Only a qualified installer/service person should install venting system. The installer must follow these safety rules:installation precautionsFailure to follow these instructions will

Wear gloves and safety glasses for protection.

Use extreme caution when using lad- ders or when on rooftops.

Be aware of electrical wiring locations in walls and ceilings.

The following actions will void the warranty on your venting system:

Installation of any damaged venting component.

A minimum of 1" clearance to all sides is required along horizontal and vertical length

12" Vertical Rise

Required Before

void the warranty.Manual backgroundManual backgroundHorizontal Run

 

A minimum 1"

 

clearance to

1”

combustibles

permitted all

 

 

around flue at

 

outside wall

 

 

50”

Min. Floor

to Center of Vent Pipe

Unauthorized modification of the vent- ing system.

Installation of any component part not manufactured or approved by MHSC.

Installation other than permitted by these instruc- tions.

 

NOTICE

Failure to follow these instructions will

 

 

 

 

void the warranty.

 

 

 

Manual backgroundManual backgroundFP2424

Figure 7 -

Combustible Clearances for Vent Pipe

WARNING

This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems.

WARNING

Horizontal and vertical sections of this vent system require a minimum of 1" clearance to combustibles on all sides, top and bottom.

10