Monessen Hearth WDV500 WDV Series Gas Fireplace, fireplace installation, Natural Gas, Propane/LP

Models: WDV500

1 48
Download 48 pages 40 Kb
Page 22
Image 22
Natural Gas

WDV Series Gas Fireplace

fireplace installation

 

 

WARNING

Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

CAUTION

A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 30

NOTE: The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CSA-B149 (1 or 2) Installation Code.

A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. Figure 30

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

CAUTION

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in

supply line as shown in Figure 30. Locate sediment trap/drip leg where it is within reach for clean- ing. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap collects moisture and contaminants and keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

Approved Flexible

Gas Line

Sediment Trap/Drip Leg

CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Tee Joint

Pipe Nipple

Cap Propane/LPManual backgroundManual background

Figure 30 -

Gas Connection

Natural Gas

From Gas Meter

(4.5" w.c. to 10.5" w.c. Pressure)

Propane/LP

From External Regulator

(11" w.c. to 13" w.c. Pressure)

22

78D0011

Page 22
Image 22
Monessen Hearth WDV500 manual WDV Series Gas Fireplace, fireplace installation, Natural Gas, Propane/LP