Installation Procedure
Electric wiring
For: AU182AEEAA
OUTDOOR UNIT
TERMINAL BLOCK
To Indoor Unit
1 2 3 | Y/G |
FIG.1
For :, AU242AGEAA, AU282AHEAA, AU362AIEAA
L N
POWER SUPPLY: 1PH,
To Indoor Unit
1 | 2 | Y/G |
3 |
OUTDOOR UNIT
TERMINAL BLOCK
FIG.2
For: AU28NAHEAA, AU36NAIEAA, AU48NAIEAA, AU60NAIEAA
To Indoor Unit
R S T | Y/G |
N 1 2 3 |
OUTDOOR UNIT TERMINAL BLOCK
POWER SUPPLY: |
|
FIG.3 | |
|
WARNING
DO NOT CONNECT THE NEUTRAL WIRE N TO R , S OR T PHASE. INTERCONNECTING WIRES MUST BE WIRED ACCORDING TO FIG.1 FIG.2 FIG.3.INCORRECT WIRING CAUSE EQUIPMENT DAMAGE.
(3)Wiring procedure
1)Remove set screws on the side before taking off the front panel toward the direction shown in figure.
2)Connect wires to the terminal block correctly and fix the wires with a wire clamp equipped nearby the terminal block.
3)Route the wires in a proper way and penetrate the wires through the opening for electric wiring on the side panel.