Bosch Appliances LBC 325X Master device, RS-232 pin description of the RS-232 to RS- 485 adapter

Page 18

Intellivox DDC Installation Manual Appendix

EN 19

 

 

Master device

As mentioned before the RS-485 network concept needs one master device. This master device (network controller) is composed of a PC running WinControl and a RS-232 to RS-485 adapter connected to the RS- 232 port of the PC. Detailed information about the WinControl program can be found in the related help file.

The RS-232 to RS-485 adapter is a small 9-pin sub-D device which can be connected to one of the computer’s serial COM ports. In the normal case the adapter is directly powered from the RS-232 terminal of the PC. The RS-232 to RS-485 adapter is not galvanically isolated. The adapter is intended for network connections during installation, maintenance or operation whenever control over specific process parameters is needed. In conjunction with the adapter a dedicated cable is needed with a 9-pin sub-D female connector and a WAGO cage clamp connector (see Table 6 to Table 8).

Master (PC)

 

9p sub-d

 

Slave (unit)

 

5p cage clamp

 

5p XLR

RS-485

Y (+send)

3

 

RS-485 A (+ receive)

1

5

 

 

 

 

 

 

 

 

RS-485

Z (-send)

 

8

 

RS-485

B (- receive)

 

2

 

4

RS-485

B (-receive)

2

 

RS-485

Z (- send)

3

3

 

 

 

 

 

 

 

 

RS-485

B (+receive)

 

7

 

RS-485

Y (+send)

 

4

 

2

Ground

1,4,5,6

 

DGND

5

1

 

 

 

 

 

 

External +9V DC (optional)

 

9

 

-

 

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

Table 6 RS-485 connection cable for use with RS-232 to RS-485 adapter.

RS-232 description

 

RS-232 pin #

NC

1

 

 

RX

 

2

TX

3

 

 

DTR

 

4

GND

5

 

 

DSR

 

6

RTS

7

 

 

CTS

 

8

+9 V

9

 

 

 

Table 7 RS-232 pin description of the RS-232 to RS- 485 adapter.

RS-485 desciption

 

RS-485 pin #

GND

1

 

 

RS-485 B (-receive)

 

2

RS-485 Y (+send)

3

 

 

GND

 

4

GND

5

 

 

GND

 

6

RS-485 B (+receive)

7

 

 

RS-485 Z (-send)

 

8

+9 V DC

9

 

 

 

Table 8 RS-485 pin description of the RS-232 to RS- 485 adapter

Bosch Security Systems July 2003

Image 18
Contents Intellivox DDC Table of contents DisclaimerFigure and Table lists Introduction Intellivox-2c shown without front grillItems in the box General considerationsList of shipped items Intellivox DDC Installation Manual Installation Guide Mains power Wiring and connectionsSignal connections Wago massive to stranded wire clampIntellivox connector block PVC insert sizes Wago 231 cross-section Connecting a WagoMethods for mounting Intellivox GeneralMeasures and dimensions LBC 3253/00 Intellivox-2c dimensions, all measures in mmMounting procedure Reference part list Grounding strategyIntellivox DDC Installation Manual Appendix Intellivox DDC Installation Manual Appendix For longer cable runs 50m Some notes on the RS-485 Network interface Structure of the RS-485 networkCable termination Network configurationCable length Cable typeMaster device RS-232 pin description of the RS-232 to RS- 485 adapterRS-485 pin description of the RS-232 to RS- 485 adapter Wiring configuration using asymmetrical cable type LBC 3262/00 Ambient SPL Temperature sensorWiring DescriptionIntellivox DDC Installation Manual Appendix Intellivox dimensions of the different models LBC 3251/00 Intellivox-1b dimensions, all measures in mmLBC 3252/00 Intellivox-2b dimensions, all measures in mm LBC 3252/10 Intellivox-2b dimensions, all measures in mm LBC 3253/00 Intellivox-2c dimensions, all measures in mm LBC 3253/10 Intellivox-2c dimensions, all measures in mm LBC 3254/00 Intellivox-4c dimensions, all measures in mm LBC 3254/10 Intellivox-4c dimensions, all measures in mm LBC 3256/00 Intellivox-6c dimensions, all measures in mm LBC 3256/10 Intellivox-6c dimensions, all measures in mm Bosch Security Systems GmbH 9922 141 50511en