1.Introduction.

This paper describes the factory recommended installation procedure for the Bosch Security Systems’ Intellivox range of controlled loudspeaker-arrays.

This type of loudspeaker-array is equipped with an on- board Digital Signal Processor (DSP) module. This manual describes mechanical matters like mounting hole positions and outlets for cable feed-through, as well as information for wiring of the connectors.

A very important parameter is the mounting height. This parameter can be very confusing, because during the acoustical design process the height of the acoustically active part of the column is optimized, while during installation the issue of interest is the physical mounting height of the column. Unfortunately there is no fixed relation between these two, because the exact position of the acoustical part of the array inside the enclosure is depending on the location of the electronics module. In the standard LBC 325x/00 versions of the Intellivox, the electronics module is mounted in the lower end of the enclosure (as it is shown in Fig 1). The LBC 325x/10 versions however, have the electronics module mounted at the top end.

Because of the extreme tight vertical radiation pattern of the Intellivox, a small deviation from the calculated acoustical mounting height may cause severe degradation of the expected performance.

For this reason the designer is advised to define two mounting heights, a physical mounting height which refers to the physical bottom side of the enclosure, and an acoustical mounting height, referring to the on-axis location of the loudspeaker at the lowest position.

Although the physical mounting positions are of primary concern to the contractor, a quick check of the acoustical height during installation will confirm the integrity of the original acoustical design.

Connector compartment

Electronics module

Reference point for acoustical mounting height

Reference point for physical mounting

height

Fig 1 Intellivox-2c shown without front grill.

Bosch Security Systems July 2003

Image 4
Contents Intellivox DDC Table of contents DisclaimerFigure and Table lists Introduction Intellivox-2c shown without front grillGeneral considerations Items in the boxList of shipped items Intellivox DDC Installation Manual Installation Guide Wiring and connections Signal connectionsMains power Wago massive to stranded wire clampIntellivox connector block Wago 231 cross-section Connecting a Wago Methods for mounting IntellivoxPVC insert sizes GeneralMeasures and dimensions LBC 3253/00 Intellivox-2c dimensions, all measures in mmMounting procedure Reference part list Grounding strategyIntellivox DDC Installation Manual Appendix Intellivox DDC Installation Manual Appendix For longer cable runs 50m Some notes on the RS-485 Network interface Structure of the RS-485 networkNetwork configuration Cable lengthCable termination Cable typeRS-232 pin description of the RS-232 to RS- 485 adapter Master deviceRS-485 pin description of the RS-232 to RS- 485 adapter LBC 3262/00 Ambient SPL Temperature sensor WiringWiring configuration using asymmetrical cable type DescriptionIntellivox DDC Installation Manual Appendix Intellivox dimensions of the different models LBC 3251/00 Intellivox-1b dimensions, all measures in mmLBC 3252/00 Intellivox-2b dimensions, all measures in mm LBC 3252/10 Intellivox-2b dimensions, all measures in mm LBC 3253/00 Intellivox-2c dimensions, all measures in mm LBC 3253/10 Intellivox-2c dimensions, all measures in mm LBC 3254/00 Intellivox-4c dimensions, all measures in mm LBC 3254/10 Intellivox-4c dimensions, all measures in mm LBC 3256/00 Intellivox-6c dimensions, all measures in mm LBC 3256/10 Intellivox-6c dimensions, all measures in mm Bosch Security Systems GmbH 9922 141 50511en