Bosch Appliances LBC 325X Methods for mounting Intellivox, PVC insert sizes, General

Page 9

Intellivox DDC Installation Manual Installation Guide

EN 10

 

 

Fig 4 WAGO 231 cross-section

Fig 5 Connecting a WAGO 231

Description

 

Wire size

 

 

 

White PVC insert

 

0.08 - 0.2 mm2

 

 

 

Light gray PVC insert

 

0.25 - 0.5 mm2

 

 

 

Dark gray PVC insert

 

0.75 - 1.0 mm2

 

 

 

Table 2 PVC insert sizes.

2.5 Methods for mounting the

Intellivox.

2.5.1 General.

For mounting of the Intellivox column there are two or three attachment points (depending on the model) each consisting of four threaded inserts at the rear of the enclosure. One point is located at the upper side, the other near the bottom and the third, if existing, at the center position. The column should be mounted using both locations. All threaded inserts are M5 metric and should only be used with the appropriate screws which are supplied with the original mounting hardware.

Fig 6

Standard Intellivox wall bracket, all dimensions in mm.

There are three options for mounting the Intellivox column.

1.The first (and most often used) mounting method of the Intellivox is by means of two or three (depending on the model) identical wall brackets. The brackets are supplied with each Intellivox and come in the same color as the enclosure. A technical drawing of the bracket is shown in Fig 6. The brackets allow mounting of the Intellivox on a straight wall or on a curved surface (pillar) while keeping a distance of 25 mm (1.0”) between the rear of the enclosure and the wall. Refer to chapter 2.5.3 for the standard mounting procedure details.

2.A second method is to mount the Intellivox using swivel brackets which allow the column to be positioned in a certain horizontal angle with respect to the wall. In this case two or three (depending on the model) swivel brackets are needed, one on the top side and one at the bottom and one in the center position if applicable. The horizontal angle of the swivel brackets can be secured by the

Bosch Security Systems July 2003

Image 9
Contents Intellivox DDC Disclaimer Table of contentsFigure and Table lists Intellivox-2c shown without front grill IntroductionItems in the box General considerationsList of shipped items Intellivox DDC Installation Manual Installation Guide Signal connections Wiring and connectionsMains power Wago massive to stranded wire clampIntellivox connector block Methods for mounting Intellivox Wago 231 cross-section Connecting a WagoPVC insert sizes GeneralLBC 3253/00 Intellivox-2c dimensions, all measures in mm Measures and dimensionsMounting procedure Grounding strategy Reference part listIntellivox DDC Installation Manual Appendix Intellivox DDC Installation Manual Appendix For longer cable runs 50m Structure of the RS-485 network Some notes on the RS-485 Network interfaceCable length Network configurationCable termination Cable typeMaster device RS-232 pin description of the RS-232 to RS- 485 adapterRS-485 pin description of the RS-232 to RS- 485 adapter Wiring LBC 3262/00 Ambient SPL Temperature sensorWiring configuration using asymmetrical cable type DescriptionIntellivox DDC Installation Manual Appendix LBC 3251/00 Intellivox-1b dimensions, all measures in mm Intellivox dimensions of the different modelsLBC 3252/00 Intellivox-2b dimensions, all measures in mm LBC 3252/10 Intellivox-2b dimensions, all measures in mm LBC 3253/00 Intellivox-2c dimensions, all measures in mm LBC 3253/10 Intellivox-2c dimensions, all measures in mm LBC 3254/00 Intellivox-4c dimensions, all measures in mm LBC 3254/10 Intellivox-4c dimensions, all measures in mm LBC 3256/00 Intellivox-6c dimensions, all measures in mm LBC 3256/10 Intellivox-6c dimensions, all measures in mm Bosch Security Systems GmbH 9922 141 50511en