Haier AB092XCERA, AB182XCERA Installation of indoor unit, After installation on the ceiling

Page 15

Installation Procedures

(3) Install a suspending bolt

To support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field.

Before going on installing, adjust space to ceiling.

 

Roof

 

Anchor bolt

~150mm

Long nut or thread

Suspending bilt M10

50

 

 

Ceiling

Note: All the above mentioned parts shall be prepared in feild, the diameter of suspending bolt is M10

3. Installation of indoor unit

<Installation Example>

In case of no ceiling Install unit temporally

Put suspending bracket on the suspending bolt to hang the unit up. Be sure to use nut and washer at both end of the breaket to secure firmly.

After installation on the ceiling

(1)Adjust unit to its right position (Refer to preparation for installation-(1)) (2)Check that unit is horzontal.

Water pump and floating switch is installed inside indoor unit,check four corners of the unit for its lever using horizontal comparator or PVC tube with water.(If unit is tilting against the direction of water drainage,problem may occur on floating water leakage.)

In the case of ceiling already exists

(1)Install unit temporally

Put suspending bracket on the suspending bolt to hang the unit up.Be sure to use nut and washer at both end of the bracket to secure it firmly.

(2)Adjust the height and position of the unit.

(3)Proceed with procedure (4) of " In the case of no ceiling "

leveler

Polythene pipe

 

Nut (Prepare in feild)

Washer (Prepared in feild)

Suspending bolts

Fasten (double nuts)

Insert

Washer fixing pad (prepared in feild)

[ secure the washer firmly]

13

Image 15
Contents No.0010577258 Contents Disposal of the old air conditioner Refrigerating circuit is leak-proof Applicable ambient temperature rangeMinute Protection Function Remote ControlMain Points of Operation Operation of Air ConditionerPrevent Cool Air Blowing Off Defrosting FunctionHints Air Inlet Grille Parts and FunctionsSwing louver Operating Control PanelSafety Cautions Dont operate the air conditioner with damp hands Clean indoor outdoor unit MaintenanceClean the unit Clean the air filterPre-season Care Seasonal Reserve Post-season CareInsufficient cooling When Trouble HappensCooled air blown out when heating Insufficient cooling or heatingUsing Directions Customer Need-to-knowCustomer Need-to-know Installation Procedures Selection of Installation PlaceInstallation Preparation Installation of indoor unit After installation on the ceilingCase of ceiling already exists Less than 75mm Less than 500mm Installation of water drainage pipeInstall ornament panel on indoor unit Installation of Ornament PanelAB092XCERA AB122XCERA Piping ConnectionWiring methods Wiring method of ring terminal Electrical WiringIndoor unit communication addresses setting Instructions to installationIndoor Followings are not malfuncition Trouble ShootingOFF Abnormal communication Haier Group