Haier AB182XCERA Refrigerating circuit is leak-proof, Applicable ambient temperature range

Page 4

Cautions

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

outdoor

DB C

35

43

10

 

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

 

WB C

14.5

--

--

 

 

 

outdoor

DB C

7

24

-15

 

WB C

6

18

--

 

 

2.If the supply cord is damaged, it must be replaced by the service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T3.15A /250VAC.

4.The wiring method should be in line with the local standard.

5.The power cable and connecting cable are self-provided.

The requirement of the communication cable:

Model

power cable

Communication cable

(sheilded wire)

 

 

 

AB092XCERA

H05RN-F 3G

(1-2.5)mm2

H05RN-F 2X(0.75-1.5)mm2

AB122XCERA

H05RN-F 3G

(1-2.5)mm2

H05RN-F 2X(0.75-1.5)mm2

AB142XCERA

H05RN-F 3G

(1-2.5)mm2

H05RN-F 2X(0.75-1.5)mm2

AB182XCERA

H05RN-F 3G

(1-2.5)mm2

H05RN-F 2X(0.75-1.5)mm2

6.The waste battery shall be disposed properly.

7.The indoor unit installation height is at least 2.5m.

2

Image 4
Contents No.0010577258 Contents Disposal of the old air conditioner Applicable ambient temperature range Refrigerating circuit is leak-proofRemote Control Main Points of OperationOperation of Air Conditioner Minute Protection FunctionDefrosting Function Prevent Cool Air Blowing OffHints Parts and Functions Swing louverOperating Control Panel Air Inlet GrilleSafety Cautions Dont operate the air conditioner with damp hands Maintenance Clean the unitClean the air filter Clean indoor outdoor unitSeasonal Reserve Post-season Care Pre-season CareWhen Trouble Happens Cooled air blown out when heatingInsufficient cooling or heating Insufficient coolingCustomer Need-to-know Using DirectionsCustomer Need-to-know Selection of Installation Place Installation ProceduresInstallation Preparation After installation on the ceiling Installation of indoor unitCase of ceiling already exists Installation of water drainage pipe Less than 75mm Less than 500mmInstallation of Ornament Panel Install ornament panel on indoor unitPiping Connection AB092XCERA AB122XCERAElectrical Wiring Wiring methods Wiring method of ring terminalInstructions to installation Indoor unit communication addresses settingIndoor Trouble Shooting Followings are not malfuncitionOFF Abnormal communication Haier Group