Graco 308149P Filters, Hydraulic Lines, Hydraulic Motor Drip Pan, Fluid Supply Hoses

Page 11
Filters

Installation

(HYDRAULIC-POWERED PUMPS)

SYSTEM ACCESSORIES

DA pressure reducing valve (H), with a drain line

(E) running into the hydraulic return line (D).

Hydraulic Lines WARNING

A fluid drain valve (M) is required in your system to help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin if you are adjusting or repairing the pump.

The fluid drain valve assists in relieving fluid pres- sure in the displacement pump, hose, and gun. Triggering the gun to relieve pressure may not be sufficient.

Mounting Accessories

Mount the pump (A) to suit the type of installation planned. Fig. 4 on page 10 illustrates a ram-mounted pump in a multi-gun header system. Pump dimensions and the mounting hole layout are shown on pages 36 and 37.

If you are mounting the pump on a air-powered ram, refer to the separate ram manual for installation and operation instructions, and recommended air accesso- ries.

Filters

Be sure your hydraulic power supply is equipped with a suction filter to the hydraulic pump and a system return line filter (AA) of 10 micron size.

Carefully follow the manufacturer’s recommendations on reservoir and filter cleaning, and periodic changes of hydraulic fluid. Use only Graco-approved hydraulic oil. Order Part No. 169236, 5 gal. (19 liter) or 207428, 1 gal. (3.8 liter). Do not substitute a lower grade oil or one with a lower flash point.

Hydraulic Lines

The motor has a 3/4 npt(f) hydraulic oil supply fitting, and a 1” npt(f) hydraulic oil return fitting. Use a mini- mum 13 mm (1/2 in.) ID hydraulic supply line, and a minimum 16 mm (5/8 in.) ID return line.

On the hydraulic supply line (C), install the following accessories in the order shown in Fig. 4, using adapt- ers as necessary:

DA shutoff valve (U) to isolate the pump for servic- ing.

DA fluid pressure gauge (F) to monitor hydraulic oil pressure to the motor and to avoid overpressurizing the motor or displacement pump, and a pressure- and temperature-compensated flow control valve (G) to prevent the motor from running too fast and possibly damaging itself.

DAn accumulator (J) to reduce the hammering effect caused by the motor reversing direction.

On the hydraulic return line (D), install the following accessories in the order shown in Fig. 4, using adapt- ers as necessary:

DA shutoff valve (V) to isolate the pump for servic- ing.

DA filter (AA) of 10 micron size.

Hydraulic Motor Drip Pan

The hydraulic motor has a drip pan to collect any leakage that may occur. Connect a 6 mm (1/4 in.) ID drain line (K) to the barbed hose fitting on the drip pan, and place the free end in a suitable container to re- ceive the drainage.

Fluid Supply Hoses

Be sure the fluid supply hose (N) is properly sized and pressure-rated for your system. Use only electrically conductive hoses. Fluid hoses must have spring guards on both ends.

Fluid Line Accessories

Install the following accessories in the positions shown in Fig. 4, using adapters as necessary:

DInstall a fluid shutoff valve (P) at each gun drop, to isolate the gun and fluid accessories for servic- ing.

DInstall a fluid drain valve (M) near the pump fluid outlet, and at each gun station. The drain valves are required in your system to relieve fluid pressure in the displacement pump, hose and gun (see the WARNING at left). Drain valves at the gun stations may be mounted in the base of a fluid regulator (L), using an adapter.

DA fluid regulator (L) controls fluid pressure to the gun/valve, and dampens pressure surges.

DA gun or valve (S) dispenses the fluid. The gun shown in Fig. 4 is a high pressure dispensing gun for highly viscous fluids.

DA gun swivel (R) allows freer gun movement.

308149 11

Image 11
Contents Part No. 246935 Pump, Series A Instructions - Parts ListCARBON STEEL Part No. 222828 Pump, Series ATable of Contents EQUIPMENT MISUSE HAZARD SymbolsWarning Symbol Caution SymbolMOVING PARTS HAZARD SKIN INJECTION HAZARDTOXIC FLUID HAZARD FIRE AND EXPLOSION HAZARDPage Grounding InstallationInstallation AIR-POWEREDPUMPSFluid Line Accessories SYSTEM ACCESSORIESMounting Accessories Air Line AccessoriesInstallation HYDRAULIC-POWEREDPUMPSFluid Supply Hoses FiltersHydraulic Lines Hydraulic Motor Drip PanPacking Nut/Wet-Cup ALL MODELS Pressure Relief ProcedureAIR-POWEREDMODELS Starting and Adjusting the Pump OperationOperation AIR-POWEREDMODELSShutdown and Care of the Pump Model 222835 ShownShutdown and Care of the Pump HYDRAULIC-POWEREDMODELSStarting and Adjusting the Pump OperationCAUSE TroubleshootingSOLUTION Required Tools ServiceDisconnecting the Displacement Pump Viscount Pumps ServiceKing, Bulldog, and Premier PumpsService Reconnecting the Displacement Pump308149 Displacement Pump DisassemblyService INTAKE CHECK VALVEService DETAIL OF PISTON CHECK VALVE Service4Remove and clean plug THROAT PACKING DETAILService ReassemblyPISTON CHECK VALVE ServiceTHROAT PACKING DETAIL DETAIL OFService Model 246935 Pump, Series A PartsModel 222828 Pump, Series A Model 222829 Pump, Series A24 1 Ratio, with Quiet King Air Motor Model 222835 Pump, Series BModel 222901 Pump, Series B Model 246936 Pump, Series A222800 Parts0919A Displacement PumpModel 222810, Series B Model 246934, Series A PartsDisplacement Pump PTFE Packing Conversion KitLeather Packing Conversion Kit Ink Pump Conversion KitModel 222828 and 246935 Bulldog Pump Technical DataTechnical Data Model 222829 Quiet Bulldog PumpTechnical Data Model 222835 and 246936 King PumpTechnical Data Model 222901 Quiet King PumpTechnical Data Model 222940 Premier Pumpliters/min Model 222902 and 246937 Viscount PumpTechnical Data liters/minPump Model DimensionsModel 222835 Shown B A E C DPremier Pumps Mounting Hole LayoutsBulldog, King, and Viscount Pumps Graco Headquarters Minneapolis Graco Standard WarrantyGraco Information FOR GRACO CANADA CUSTOMERS