Technical Data
(Model 222901 Quiet King Pump)
Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24:1 (Quiet King Air Motor) Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . 16.6 MPa, 166 bar (2400 psi) Maximum air input pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.7 MPa, 7 bar (100 psi) Pump cycles per 3.8 liters (1 gal.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Recommended pump speed for continuous operation . . . . . . . . . . . . . . . . . . 50 cycles per min Maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.75 liters/min (7.5 gpm) at 50 cycles/min Air motor piston effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506 cm@ (78.5 in.@) Stroke length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 mm (4.75 in.) Displacement pump effective area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 cm@ (3.255 in.@) Maximum pump operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.5_C (150_F) Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/4 npsm(f) Fluid outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
304 and
KEY: Fluid Outlet Pressure – Black Curves | A | 0.63 MPa, 6.3 bar (90 psi) Air Pressure |
Air Consumption – Gray Curves | B | 0.49 MPa, 4.9 bar (70 psi) Air Pressure |
| C | 0.28 MPa, 2.8 bar (40 psi) Air Pressure |
NOTE: Recommended pump speed for continuous operation (to shaded area): 50 cpm
psi |
|
|
|
|
|
| psi |
|
|
|
|
|
|
bar |
| cycles/min |
|
| scfm | bar |
| cycles/min |
|
| scfm | ||
MPa | 16 | 32 | 48 50 | 64 | 80 | m#/min | MPa | 8 | 16 | 24 | 32 | 40 | m#/min |
|
| ||||||||||||
2000 |
|
|
|
|
| 300 | 2000 |
|
|
|
|
| 300 |
140 | A |
|
|
|
| 8.40 | 140 |
|
|
|
|
| 8.40 |
14.0 |
|
|
|
|
|
| 14.0 | A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
1600 |
|
|
| A |
| 240 | 1600 |
|
|
|
|
| 240 |
112 | B |
|
|
|
| 6.72 | 112 |
|
|
|
|
| 6.72 |
11.2 |
|
|
|
|
| 11.2 | B |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
1200 |
|
|
|
|
| 180 | 1200 |
|
|
|
|
| 180 |
|
|
|
|
| 5.04 |
|
|
|
|
| 5.04 | ||
84 |
|
|
| B |
| 84 |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |||
8.4 |
|
|
|
|
|
| 8.4 |
|
|
|
|
|
|
800 | C |
|
|
|
| 120 | 800 | C |
|
|
|
| 120 |
|
|
|
|
|
|
|
| 3.36 | |||||
56 |
|
|
| C |
| 3.36 | 56 |
|
| A |
| ||
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| B |
| ||||
5.6 |
|
|
|
|
|
| 5.6 |
|
|
|
|
| |
400 |
|
|
|
|
| 60 | 400 |
|
|
|
|
| 60 |
|
|
|
|
| 1.68 |
|
|
| C |
| 1.68 | ||
28 |
|
|
|
|
| 28 |
|
|
|
| |||
2.8 |
|
|
|
|
|
| 2.8 |
|
|
|
|
|
|
0 |
|
|
|
|
|
| 0 |
|
|
|
|
|
|
gpm 0 | 2 | 4 | 6 | 8 | 10 | gpm 0 | 1 | 2 | 3 | 4 | 5 |
| |
liters/min | 7.6 | 15.2 | 22.8 | 30.4 | 38.0 | liters/min | 3.8 | 7.6 | 11.4 | 15.2 | 19.0 |
| |
|
| FLUID FLOW |
|
|
|
|
| FLUID FLOW |
|
|
| ||
| (TEST FLUID: 100,000 CENTIPOISE SEALANT) |
|
| (TEST FLUID: 4,000,000 CENTIPOISE SILICON) |
|
To find Fluid Outlet Pressure (MPa/bar/psi) at a specific fluid flow | To find Pump Air Consumption (m#/min or scfm) at a specific fluid | |||
(lpm/gpm) and operating air pressure (MPa/bar/psi): | flow (lpm/gpm) and air pressure (MPa/bar/psi): | |||
1. | Locate desired flow along bottom of chart. | 1. | Locate desired flow along bottom of chart. | |
2. | Follow vertical line up to intersection with selected fluid outlet | |||
|
| |||
| pressure curve (black). Follow left to scale to read fluid outlet | 2. | Read vertical line up to intersection with selected air consumption | |
| pressure. |
| curve (gray). Follow right to scale to read air consumption. |
308149 33