Graco 308149P important safety instructions Installation, Grounding

Page 7
Installation

Installation

Grounding

WARNING

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 5.

1. King Pumps: use a ground wire and clamp. See

Fig. 1. Remove the ground screw (Z) and insert

through eye of ring terminal at the end of ground

wire (Y). Fasten ground screw back onto pump

and tighten securely. Connect the other end of the

wire to a true earth ground. Order Part No. 222011

Ground Wire and Clamp.

All Other Pumps: use a ground wire and clamp.

See Fig. 2. Loosen the grounding lug locknut (W)

and washer (X). Insert one end of a 1.5 mm@ (12

ga) minimum ground wire (Y) into the slot in lug (Z)

and tighten the locknut securely. Connect the other

end of the wire to a true earth ground. Order Part

No. 237569 Ground Wire and Clamp.

7.Object being sprayed: according to your local code.

8.All solvent pails used when flushing, according to your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity.

9.To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the spray gun/dispensing valve firmly to the side of a grounded metal pail, then trigger the gun/valve.

ZGrounding Y

2. Air and hydraulic hoses: use only electrically

conductive hoses.

Fig. 1

TI1052

3.

Fluid hoses: use only electrically conductive fluid

 

hoses.

4.

Air compressor or hydraulic power supply: follow

 

manufacturer’s recommendations.

5.

Spray gun/dispensing valve: grounding is obtained

 

through connection to a properly grounded fluid

 

hose and pump.

6.

Fluid supply container: according to your local

 

code.

W

X

Y

Z

Fig. 2

0864

308149 7

Image 7
Contents Part No. 246935 Pump, Series A Instructions - Parts ListCARBON STEEL Part No. 222828 Pump, Series ATable of Contents EQUIPMENT MISUSE HAZARD SymbolsWarning Symbol Caution SymbolMOVING PARTS HAZARD SKIN INJECTION HAZARDTOXIC FLUID HAZARD FIRE AND EXPLOSION HAZARDPage Grounding InstallationInstallation AIR-POWEREDPUMPSFluid Line Accessories SYSTEM ACCESSORIESMounting Accessories Air Line AccessoriesInstallation HYDRAULIC-POWEREDPUMPSFluid Supply Hoses FiltersHydraulic Lines Hydraulic Motor Drip PanPacking Nut/Wet-Cup ALL MODELS Pressure Relief ProcedureAIR-POWEREDMODELS Starting and Adjusting the Pump OperationOperation AIR-POWEREDMODELSShutdown and Care of the Pump Model 222835 ShownShutdown and Care of the Pump HYDRAULIC-POWEREDMODELSStarting and Adjusting the Pump OperationSOLUTION TroubleshootingCAUSE Disconnecting the Displacement Pump ServiceRequired Tools Viscount Pumps ServiceKing, Bulldog, and Premier PumpsService Reconnecting the Displacement Pump308149 Displacement Pump DisassemblyService INTAKE CHECK VALVEService DETAIL OF PISTON CHECK VALVE Service4Remove and clean plug THROAT PACKING DETAILService ReassemblyPISTON CHECK VALVE ServiceTHROAT PACKING DETAIL DETAIL OFService Model 246935 Pump, Series A PartsModel 222828 Pump, Series A Model 222829 Pump, Series A24 1 Ratio, with Quiet King Air Motor Model 222835 Pump, Series BModel 222901 Pump, Series B Model 246936 Pump, Series A222800 Parts0919A Displacement PumpModel 222810, Series B Model 246934, Series A PartsDisplacement Pump PTFE Packing Conversion KitLeather Packing Conversion Kit Ink Pump Conversion KitModel 222828 and 246935 Bulldog Pump Technical DataTechnical Data Model 222829 Quiet Bulldog PumpTechnical Data Model 222835 and 246936 King PumpTechnical Data Model 222901 Quiet King PumpTechnical Data Model 222940 Premier Pumpliters/min Model 222902 and 246937 Viscount PumpTechnical Data liters/minPump Model DimensionsModel 222835 Shown B A E C DBulldog, King, and Viscount Pumps Mounting Hole LayoutsPremier Pumps Graco Headquarters Minneapolis Graco Standard WarrantyGraco Information FOR GRACO CANADA CUSTOMERS