Service
16.Lubricate the throat packings and glands, and install them in the outlet housing (19) one at a time in the following order, with the lips of the
17.Lubricate the seal (39*) and place it on the top edge of the cylinder (4). Set the outlet housing (19) on top of the cylinder.
18.Install the six long capscrews (32) through the outlet housing (19) and into the intake housing
(17).Using a socket wrench, torque the screws oppositely and evenly to
19.Check that the flats of the priming piston rod (12) are accessible below the intake housing (17). If not, tap on the top of the displacement rod (1) with a rubber mallet, until the flats are exposed.
20.Slide the priming piston guide (13) onto the rod
(12)until it stops. Then install the priming piston (15), with the flat side facing up toward the pump. Apply thread sealant to the threads of the priming piston nut (14). Hold the rod (12) steady with an adjustable wrench on the flats, and screw the nut
(14)onto the rod with another wrench. Torque to
12
13
1 | 15 | 14 | 2 | 3 |
1Flat side must face up.
2Apply thread sealant.
3Torque to
01165
Fig. 12
21.Reconnect the displacement pump to the air motor as explained on page 18.
22.Allow 2 hours for the thread sealant to cure before returning the pump to service.
24 308149