5.Replace burners and manifold, inspect the burner assembly for proper seating of burners in retention slots.

6.Reconnect electrical power and gas supply.

CAUTION

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION.

CAUTION

ALWAYS VERIFY PROPER OPERATION AFTER SERVICING.

For further information on the yearly inspection, consult the User Manual. It is recommended that a qualified servicer inspect and service the unit at least once each year.

Turn the unit on at the thermostat. Wait a few minutes, since any dislodged dust will alter the normal flame appearance. Flames should be predominantly blue and directed into the tubes. They should not be yellow. They should extend directly outward from the burner ports without curling downward, floating or lifting off the ports.

ACCESSORIES AND FUNCTIONAL PARTS

SHEET METAL ACCESSORIES

Additional accessories can be purchased to fit specific application needs. Parts and instructions are available from your distributor.

FUNCTIONAL PARTS

FUNCTIONAL PARTS

Auxiliary Limit Switch

Flame Roll-out Switch

Blower Housing

Flame Sensor

Circulator Blower Motor

Gas Orifice

Blower W heel

Gas Valve

Burner

Heat Exchanger

Capacitor

High Limit Switch

Compressor

Igniter

Condenser Coil

Ignition Control

Condenser Fan Blade

Induced Draft Blower

Condenser Fan Motor

Pressure Switch

Contactor

Pressure Switch Hose

Gas Manifold

Transformer

Evaporator Coil

 

Functional Parts List

GENERAL INFORMATION

1.Refer to the description in Functional Parts List when ordering any of the listed functional parts. Be sure to provide the unit model and serial numbers with the order.

2.Although only functional parts are shown, all sheet metal parts, doors, etc. may be ordered by description.

3.Parts are available from your distributor.

18

Image 18
Contents GPG13 M Series W/R410A Ansi Z21.47CSA-2.3 Central FurnacesPropane Gas Installations Replacement PartsSafety Instructions Electrical WiringReplacement Parts Safety InstructionsUnit Location Carbon Monoxide Poisoning HazardRoof Curb Installation Outside Slab InstallationRooftop Installation General InformationRigging Details GAS PipingRigging Natural Gas Connection Proper Piping PracticeElectrical Wiring Typical Propane Gas PipingPropane Gas Pipe Sizing Low Voltage Wiring Typical Electrical Wiring Unit VoltageFilter Installation Typical Thermostat and Unit 24 V Wiring HookupDuct Cover Installation Down Discharge Applications Circulating AIR and FiltersCondensate Drain STARTUP, ADJUSTMENTS, and ChecksVenting Normal Sequences of OperationWhite-Rodgers 36G22 Secondary Limit Control Pre-Operation ChecksWhite-Rodgers Model 36G22 Honeywell Model VR8215 Single-StageGas Input Natural Gas Only Check Temperature Rise CheckBlower Speed Adjustments Main Burner Flame CheckTroubleshooting Maintenance Manifold Assembly Flame SensorBurner Flame Accessories and Functional Parts Functional Parts ListBlower Performance Data Single Phase CFM Watts Amps RiseRemoved AA & Used a T1 Heating Speed T2 Heating Speed T3 Heating Speed CFM Watts AmpsPG136090M41A* Rise Range 45 Blower Performance Data Heating Speeds Three Phase CFM RPMCFM Watts RPM Amps Heating Timing Chart Appendix Unit Dimensions PG1324,30,36,421** Wiring Diagram INSTALLER/SERVICEMAN THC-FIELD Wiring YL RD BL BL BLINSTALLER/SERVICEMAN Thermostat Field Wiring VMRGPG13363** Wiring Diagram INSTALLER/SERVICEMAN EconomizerGPG1348,603** Wiring Diagram BL BL BL RD RDOption Minimum Clearances Recommended Filter SizesThat’s why we know. . .There’s No Better Quality Quality Makes the Difference

A/GPG13 M specifications

Goodman Manufacturing is known for producing high-quality HVAC systems, and one of its standout offerings is the Goodman A/GPG13 M series. This air conditioning and heating unit delivers exceptional performance, reliability, and efficiency, making it a preferred choice for residential settings.

The Goodman A/GPG13 M is specifically designed to provide homeowners with an efficient and affordable solution for climate control. One of its main features is the energy-efficient compressor, which operates with a SEER rating of up to 13, ensuring reduced electricity consumption while effectively cooling your living space. This efficiency not only minimizes utility bills but also helps to lower your carbon footprint.

Another standout characteristic of the Goodman A/GPG13 M is its durable construction. The unit is engineered with a heavy-gauge, galvanized steel cabinet that has a polyester finish, providing protection against rust and corrosion. This durability ensures that the system can withstand the elements and lasting performance even in challenging climates.

The Goodman A/GPG13 M series also boasts advanced technology to enhance comfort levels in any home. The unit is equipped with a two-stage cooling system that can adjust to varying temperature demands, ensuring that your living space remains comfortable throughout the hot summer months. Additionally, the unit includes a multi-speed blower for more even air distribution, enhancing overall comfort.

Furthermore, the Goodman A/GPG13 M complies with rigorous environmental standards. It uses R-410A refrigerant, which is more environmentally friendly than older refrigerants like R-22, making it an excellent choice for eco-conscious consumers.

Installation of the Goodman A/GPG13 M is made easier with its lightweight design and user-friendly features, allowing HVAC professionals to install the system efficiently. The unit is backed by a comprehensive warranty, reflecting Goodman Manufacturing’s commitment to quality and customer satisfaction.

In summary, the Goodman A/GPG13 M series showcases an impressive combination of energy efficiency, durable construction, advanced technology, and eco-friendly refrigerant choices. It represents an ideal option for homeowners who seek a reliable HVAC solution that delivers consistent comfort while maintaining an eye on energy consumption and environmental impact.