Goodman Mfg A/GPG13 M operating instructions Heating Timing Chart

Page 25

IGNITION CONTROL DIAGNOSTIC INDICATOR CHART

Light Signal

Refer to Abnormal Heating or Cooling Operation Sections of this Manual

Off

Internal Control Failure

1 Flash

External Lockout

2 Flashes

Pressure Switch Stuck Open

3 Flashes

Pressure Switch Stuck Closed

4 Flashes

Thermal Protection Device Open

5 Flashes

Flame Detected with Gas Valve Closed

6 Flashes

Short Cycle Compressor Delay (Cooling Only)

 

 

HEATING TIMING CHART

100 %

Circulator

Blower OFF

Gas Valve

ON

OFF

Igniter ON

OFF

Induced ON

Draft OFF

Blower

ON

Thermostat OFF

Seconds

0

15

22

45

52

0

29

120, 135,150

COOLING TIMING CHART

Circulator

ON

100%

Blower

OFF

 

Outdoor Fan

ON

 

and

OFF

 

Compressor

 

 

Thermostat

ON

 

OFF

 

 

 

25

Image 25
Contents Ansi Z21.47CSA-2.3 Central Furnaces GPG13 M Series W/R410ASafety Instructions Replacement PartsPropane Gas Installations Electrical WiringSafety Instructions Replacement PartsCarbon Monoxide Poisoning Hazard Unit LocationRooftop Installation Outside Slab InstallationRoof Curb Installation General InformationGAS Piping Rigging DetailsRigging Proper Piping Practice Natural Gas ConnectionTypical Propane Gas Piping Electrical WiringPropane Gas Pipe Sizing Typical Electrical Wiring Unit Voltage Low Voltage WiringDuct Cover Installation Down Discharge Applications Typical Thermostat and Unit 24 V Wiring HookupFilter Installation Circulating AIR and FiltersVenting STARTUP, ADJUSTMENTS, and ChecksCondensate Drain Normal Sequences of OperationSecondary Limit Control Pre-Operation Checks White-Rodgers 36G22Honeywell Model VR8215 Single-Stage White-Rodgers Model 36G22Blower Speed Adjustments Temperature Rise CheckGas Input Natural Gas Only Check Main Burner Flame CheckTroubleshooting Maintenance Flame Sensor Manifold AssemblyBurner Flame Functional Parts List Accessories and Functional PartsCFM Watts Amps Rise Blower Performance Data Single PhaseRemoved AA & Used a CFM Watts Amps T1 Heating Speed T2 Heating Speed T3 Heating SpeedPG136090M41A* Rise Range 45 Blower Performance Data Heating Speeds Three Phase RPM CFMCFM Watts RPM Amps Heating Timing Chart Appendix Unit Dimensions PG1324,30,36,421** Wiring Diagram INSTALLER/SERVICEMAN THC-FIELD Wiring BL BL BL YL RDVMR INSTALLER/SERVICEMAN Thermostat Field WiringGPG13363** Wiring Diagram Economizer INSTALLER/SERVICEMANBL BL BL RD RD GPG1348,603** Wiring DiagramOption Recommended Filter Sizes Minimum ClearancesQuality Makes the Difference That’s why we know. . .There’s No Better Quality

A/GPG13 M specifications

Goodman Manufacturing is known for producing high-quality HVAC systems, and one of its standout offerings is the Goodman A/GPG13 M series. This air conditioning and heating unit delivers exceptional performance, reliability, and efficiency, making it a preferred choice for residential settings.

The Goodman A/GPG13 M is specifically designed to provide homeowners with an efficient and affordable solution for climate control. One of its main features is the energy-efficient compressor, which operates with a SEER rating of up to 13, ensuring reduced electricity consumption while effectively cooling your living space. This efficiency not only minimizes utility bills but also helps to lower your carbon footprint.

Another standout characteristic of the Goodman A/GPG13 M is its durable construction. The unit is engineered with a heavy-gauge, galvanized steel cabinet that has a polyester finish, providing protection against rust and corrosion. This durability ensures that the system can withstand the elements and lasting performance even in challenging climates.

The Goodman A/GPG13 M series also boasts advanced technology to enhance comfort levels in any home. The unit is equipped with a two-stage cooling system that can adjust to varying temperature demands, ensuring that your living space remains comfortable throughout the hot summer months. Additionally, the unit includes a multi-speed blower for more even air distribution, enhancing overall comfort.

Furthermore, the Goodman A/GPG13 M complies with rigorous environmental standards. It uses R-410A refrigerant, which is more environmentally friendly than older refrigerants like R-22, making it an excellent choice for eco-conscious consumers.

Installation of the Goodman A/GPG13 M is made easier with its lightweight design and user-friendly features, allowing HVAC professionals to install the system efficiently. The unit is backed by a comprehensive warranty, reflecting Goodman Manufacturing’s commitment to quality and customer satisfaction.

In summary, the Goodman A/GPG13 M series showcases an impressive combination of energy efficiency, durable construction, advanced technology, and eco-friendly refrigerant choices. It represents an ideal option for homeowners who seek a reliable HVAC solution that delivers consistent comfort while maintaining an eye on energy consumption and environmental impact.