Goodman Mfg A/GPG13 M Blower Performance Data Single Phase, CFM Watts Amps Rise

Page 19

BLOWER PERFORMANCE DATA - SINGLE PHASE

 

 

 

 

*PG1324045M41A* - Rise Range: 30° - 60°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

LOW

 

 

MEDIUM

 

 

HIGH

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

600

150

0.67

57

850

230

1.02

40

1,190

380

1.67

NR

0.2

570

140

0.65

60

830

220

1.00

41

1,140

360

1.62

NR

0.3

510

130

0.63

NR

765

215

0.97

45

1,080

350

1.58

32

0.4

450

125

0.61

NR

715

210

0.94

48

1,025

340

1.54

33

0.5

380

120

0.58

NR

660

205

0.90

52

975

330

1.38

35

0.6

--------

--------

--------

NR

610

195

0.88

56

920

310

1.37

37

0.7

--------

--------

--------

NR

--------

--------

--------

NR

830

300

1.35

41

0.8

--------

--------

--------

NR

--------

--------

--------

NR

730

290

1.32

47

*PG1324070M41A* - Rise Range: 35° - 65°

Unit

 

LOW

 

 

MEDIUM

 

 

HIGH

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

600

150

0.67

NR

850

230

1.02

NR

1,190

380

1.67

43

0.2

570

140

0.65

NR

830

220

1.00

NR

1,140

360

1.62

45

0.3

510

130

0.63

NR

765

215

0.97

NR

1,080

350

1.58

47

0.4

450

125

0.61

NR

715

210

0.94

NR

1,025

340

1.54

50

0.5

380

120

0.58

NR

660

205

0.90

NR

975

330

1.38

52

0.6

--------

--------

--------

NR

610

195

0.88

NR

920

310

1.37

56

0.7

--------

--------

--------

NR

--------

--------

--------

NR

830

300

1.35

62

0.8

--------

--------

--------

NR

--------

--------

--------

NR

730

290

1.32

NR

*PG1330045M41A* - Rise Range: 30° - 60°

Unit

 

LOW

 

 

MEDIUM

 

 

HIGH

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1,056

350

1.51

33

1,261

452

1.95

NR

1,370

509

2.23

NR

0.2

1,010

339

1.43

34

1,221

442

1.90

NR

1,310

492

2.13

NR

0.3

971

343

1.45

36

1,174

428

1.84

NR

1,262

489

2.09

NR

0.4

937

329

1.41

37

1,125

414

1.80

31

1,208

475

2.06

NR

0.5

878

318

1.27

39

1,063

398

1.70

32

1,140

453

1.93

30

0.6

811

306

1.29

43

1,004

380

1.66

34

1,081

440

1.90

32

0.7

723

291

1.21

48

919

368

1.59

38

1,006

425

1.88

34

0.8

545

259

1.10

NR

796

371

1.46

43

879

403

1.74

39

*PG133070M41A* - Rise Range: 35° -65°

Unit

 

LOW

 

 

MEDIUM

 

 

HIGH

 

Static

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

CFM

WATTS

AMPS

RISE

0.1

1,056

350

1.51

49

1,261

452

1.95

41

1,370

509

2.23

38

0.2

1,010

339

1.43

51

1,221

442

1.90

42

1,310

492

2.13

40

0.3

971

343

1.45

53

1,174

428

1.84

44

1,262

489

2.09

41

0.4

937

329

1.41

55

1,125

414

1.80

46

1,208

475

2.06

43

0.5

878

318

1.27

59

1,063

398

1.70

49

1,140

453

1.93

45

0.6

811

306

1.29

64

1,004

380

1.66

52

1,081

440

1.90

48

0.7

723

291

1.21

NR

919

368

1.59

56

1,006

425

1.88

NR

0.8

545

259

1.10

NR

796

371

1.46

65

879

403

1.74

NR

NR = Heating Temperature Rise Not Recommended.

NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, external static pressure should not exceed 0.5" w.c.

19

Image 19
Contents Ansi Z21.47CSA-2.3 Central Furnaces GPG13 M Series W/R410AElectrical Wiring Replacement PartsSafety Instructions Propane Gas InstallationsSafety Instructions Replacement PartsCarbon Monoxide Poisoning Hazard Unit LocationGeneral Information Outside Slab InstallationRooftop Installation Roof Curb InstallationGAS Piping Rigging DetailsRigging Proper Piping Practice Natural Gas ConnectionTypical Propane Gas Piping Electrical WiringPropane Gas Pipe Sizing Typical Electrical Wiring Unit Voltage Low Voltage WiringCirculating AIR and Filters Typical Thermostat and Unit 24 V Wiring HookupDuct Cover Installation Down Discharge Applications Filter InstallationNormal Sequences of Operation STARTUP, ADJUSTMENTS, and ChecksVenting Condensate DrainSecondary Limit Control Pre-Operation Checks White-Rodgers 36G22Honeywell Model VR8215 Single-Stage White-Rodgers Model 36G22Main Burner Flame Check Temperature Rise CheckBlower Speed Adjustments Gas Input Natural Gas Only CheckTroubleshooting Maintenance Flame Sensor Manifold AssemblyBurner Flame Functional Parts List Accessories and Functional PartsCFM Watts Amps Rise Blower Performance Data Single PhaseRemoved AA & Used a CFM Watts Amps T1 Heating Speed T2 Heating Speed T3 Heating SpeedPG136090M41A* Rise Range 45 Blower Performance Data Heating Speeds Three Phase RPM CFMCFM Watts RPM Amps Heating Timing Chart Appendix Unit Dimensions PG1324,30,36,421** Wiring Diagram INSTALLER/SERVICEMAN THC-FIELD Wiring BL BL BL YL RDVMR INSTALLER/SERVICEMAN Thermostat Field WiringGPG13363** Wiring Diagram Economizer INSTALLER/SERVICEMANBL BL BL RD RD GPG1348,603** Wiring DiagramOption Recommended Filter Sizes Minimum ClearancesQuality Makes the Difference That’s why we know. . .There’s No Better Quality

A/GPG13 M specifications

Goodman Manufacturing is known for producing high-quality HVAC systems, and one of its standout offerings is the Goodman A/GPG13 M series. This air conditioning and heating unit delivers exceptional performance, reliability, and efficiency, making it a preferred choice for residential settings.

The Goodman A/GPG13 M is specifically designed to provide homeowners with an efficient and affordable solution for climate control. One of its main features is the energy-efficient compressor, which operates with a SEER rating of up to 13, ensuring reduced electricity consumption while effectively cooling your living space. This efficiency not only minimizes utility bills but also helps to lower your carbon footprint.

Another standout characteristic of the Goodman A/GPG13 M is its durable construction. The unit is engineered with a heavy-gauge, galvanized steel cabinet that has a polyester finish, providing protection against rust and corrosion. This durability ensures that the system can withstand the elements and lasting performance even in challenging climates.

The Goodman A/GPG13 M series also boasts advanced technology to enhance comfort levels in any home. The unit is equipped with a two-stage cooling system that can adjust to varying temperature demands, ensuring that your living space remains comfortable throughout the hot summer months. Additionally, the unit includes a multi-speed blower for more even air distribution, enhancing overall comfort.

Furthermore, the Goodman A/GPG13 M complies with rigorous environmental standards. It uses R-410A refrigerant, which is more environmentally friendly than older refrigerants like R-22, making it an excellent choice for eco-conscious consumers.

Installation of the Goodman A/GPG13 M is made easier with its lightweight design and user-friendly features, allowing HVAC professionals to install the system efficiently. The unit is backed by a comprehensive warranty, reflecting Goodman Manufacturing’s commitment to quality and customer satisfaction.

In summary, the Goodman A/GPG13 M series showcases an impressive combination of energy efficiency, durable construction, advanced technology, and eco-friendly refrigerant choices. It represents an ideal option for homeowners who seek a reliable HVAC solution that delivers consistent comfort while maintaining an eye on energy consumption and environmental impact.